Resolved issues

If you are upgrading from a previous version of NetVault Backup, verify that none of the existing NetVault Backup users have an @ symbol in their User Name. Update the User Name for any users whose name does contain an @ symbol. NetVault Backup assumes that a name that contains @ is a domain user and automatically tries to authenticate it with AD when the user logs on. If an existing user tries to log on and NetVault Backup is unable to authenticate the user with AD because the credentials do not match, login fails.

This is documented as designed.

DNAD-523, DNAD-562

If you ran parallel backup or restore jobs on an AIX client with a QoreStor target, the jobs failed with a “Job Manger has lost the message channel unexpected” error message.

DNR3-870, QS‑4252

When many backup jobs that target the same disk-based storage device are scheduled to start at the same time or within a small window of time, the following issues occur:

For information on working around this issue, see “Troubleshooting” in the Quest NetVault Backup Administrator’s Guide.

DNR3-1072, NVBU-12089 (28204)

Starting with NetVault Backup 10.0.1, the built-in plug-ins used four-digit version numbers (for example, 10.1.1.1).

If you install the built-in plug-ins available with 10.0.1 and later on a machine running NetVault Backup 10.0, the About dialog box displayed the correct 4-digit version number, but the other WebUI pages (for example, the Manage Clients page) displayed 3-digit version numbers with incorrect release numbers (for example, 10.0.257 instead of 10.0.1).

Similarly, if you installed a plug-in that used the old version format on NetVault Backup 10.0.1 and later, the About dialog box displayed the correct version number (for example, 2.6.5), but the other WebUI pages displayed incorrect release and build numbers (for example, 2.6.0.5).

The About dialog box displays the correct version number of a built-in plug-in.

NVBU-10927 (26687)

The Drive Transfer Buffer Size option is now set to 8 MiB by default. To ensure that this configuration is supported on your system, verify your OS settings before adding a tape device. If this value is too high, change it to 257 KiB in the template file. For information on working around this issue, see the “Changing the default Drive Transfer Buffer Size option” topic in the Quest NetVault Backup Administrator’s Guide.

NVBU-11305 (27165)

On Windows 2012, the Plug-in for Databases fails to restore a NetVault Database backup that is stored in a NetVault SmartDisk device. For information on working around this issue, see “Troubleshooting” in the Quest NetVault Backup Administrator’s Guide.

NVBU-11307 (27167)

Dual media requests were handled sequentially, which caused performance issues.

NVBU-11971, NVBU-19715, NVBU-19782, NVBU-19786

If a deployment task was stopped — or the Deployment Manager or NetVault Backup Service shut down — while a task was still running, the task status was set to “Complete” and the individual targets were marked as “Completed with Errors” even if the software packages were successfully installed on the target machine.

NVBU-13433 (30274)

The shared directory path for push installations could not contain non-English characters, such as on a Japanese Windows-based machine.

NVBU-13564 (30451)

NetVault Backup is unable to send reports as an email attachment in PDF format on RHEL 5.x platform. For information on working around this issue, see “Troubleshooting” in the Quest NetVault Backup Administrator’s Guide.

NVBU-14529 (31878)

If you aborted a backup job while the job was in “Writing to the media” state, the media was marked as Full.

NVBU-18830, NVBU-19781

Data Copy jobs would hang when copying from an RAS device to tape.

NVBU-19122, NVBU-19783

Corrected the issue of when NetVault Backup 12.4 was used in the NetVault Backup Server, then Oracle CLI jobs from any NetVault Backup Client did not work and the Job Manager on the NetVault Backup Server quit after it attempted to access an oPluginOptionsScreen object that was null.

NVBU-19634

If multiple Data Copy jobs started at the same time and one of them went into a ‘waiting’ state, then all Data Copy jobs became stuck in a ‘waiting for media’ state.

NVBU-19682, NVBU-19784

Dual media requests and Scan media requests entered the queue with a priority of 0 instead of 1.

NVBU-19690, NVBU-19785

Job Status page would hang when 160 jobs were simultaneously in ‘running’ state.

NVBU-19694

Removed mini dual media requests from the Data Copy plug-in, as dual media requests make them unnecessary.

NVBU-19721

Reduced polling for Manage Devices and Job Status pages.

NVBU-19722

Corrected an issue where memory consumption gradually increased when the nvpmgr process was in an idle state.

NVBU-19758

Known issues

If you are using Huawei OceanStor Device Manager and a snapshot is mounted on multiple NetVault Backup clients, unmounting that snapshot from any one of the NetVault Backup Clients also unmounts the snapshot from all NetVault Backup Clients.

NV-64, NVBU‑18684

While editing a restore selection set on the Edit Selection Set page, the Next button is disabled.

Workaround: Select or clear the data selection tree check box on the Edit Selection Set page.

NVBU-16148

The diagnostic data for some NetVault Backup Client machines with an older configuration is intermittently collected only partially due to a timeout.

Workaround: Increase the value in the Physical Client Long Timeout field of the Web Service dialog box.

NVBU-15735

Quest DR Device is not accessible after you change the DR Device user password.

NVBU-15843

CLI displaying non English characters incorrectly. For example,

NVBU-13974 (31104)

The restore job from NDMP backup data copied to 256Kib drive fails and displays an “NDMP data does not start on a block boundary” error message.

Workaround: https://support.quest.com/netvault-backup/kb/212701

DNNDMP-657 (31825)

On the Manage Devices page, in Tree View, clicking Scan starts scanning the selected slot, drive, or library immediately. It does not show the Minimum life for imported backups (days) dialog box or confirmation message.

NVBU-14745 (32197)

On the Manage Devices page, in Tree View, you cannot select multiple media from the list of available media for a bulk blank operation.

NVBU-14758 (32214)

On the Manage Devices page, in Tree View, you cannot select multiple media from the list of available media for a bulk label operation.

NVBU-14759 (32215)

When performing backups with the NetVault Backup Plug-in for Teradata, if the number of parallel streams exceeds the SoftStreamLimit set for the target NetVault SmartDisk, the backup job stops responding.

NVBU-389 (1948)

When a backup that is configured as “restartable” is duplicated, only the data backed up in the last restarted instance of the job is duplicated.

NVBU-1160 (3971, (NVG‑4022)

In NetVault Backup with a non-English locale, the Running Status field does not display a current job status as the output of nvreport command and Report Job.

NVBU-1186 (3997) (NVG‑4206)

On Linux- and UNIX-based systems, the progress message that is displayed during NetVault Backup installation is displayed correctly only if the system is configured to use the UTF-8 character set.

NVBU-10588 (26249)

If the Network Manager process (nvnmgr) stops responding due to any error and fails to exit properly, it prevents the NetVault Backup Service from starting on that machine.

Workaround: If this error occurs, manually stop or end the nvnmgr process before restarting the NetVault Backup Service.

NVBU-11005 (26778)

After upgrading to Firefox 31, if you try to log in to the NetVault Backup WebUI, the following error message is displayed:

Issuer certificate is invalid. (Error code: sec_error_ca_cert_invalid)

The new security library security.use_mozillapkix_verification raises this certification error when you try to access a self-signed certificate.

Workaround: To resolve this issue, do the following:

2
Locate the preference security.use_mozillapkix_verification, and set it to false.

NVBU-11321 (27189)

On Windows, if a copy of a “.cfg” file is created in the <NetVault Backup home>/config directory, the WebUI may display empty or partly empty dialog boxes when the settings are accessed from the Change Settings page after restarting the service.

NVBU-12734 (29149)

Under certain conditions, the NetVault Backup Server may be unable to determine the status of the push installation task on a remote client. In such cases, the task status may remain in the “Running” state. This error can occur under the following conditions:

Subsequent tasks remain in a “Pending” state until you cancel the previous task.

NVBU-13610 (30508)

When performing push installations, if you use any illegal characters in the machine password for a new client, the remote installer reports an error and fails to install the software on the client.

NVBU-13632 (30537)

If the server IP address is used to configure a local package store (for example, \\10.11.12.3\PkgStore), the user credentials are not validated when the package store is added or updated. If you specify invalid credentials, no errors are reported. However, the deployment task fails if the authentication fails and the packages cannot be retrieved from the store. Therefore, Quest recommends that you use the server name when configuring the path to a local store (for example, \\WinServer1\PkgStore).

NVBU-13647 (30558)

Known issues related to Plug-in for RDA on Solaris:

Backing up file system data from Solaris clients to DR Series Systems: When you perform file system backups to DR Series systems, the backups run in the Passthrough mode by default. You can change the default setting on the DR Series system to run backups in the Dedupe mode, but you may experience slow backup performance in this mode.
Restoring data from a DR Series System to a Solaris Client: When you run multiple restore jobs at the same time, it can affect the performance of individual jobs and result in low aggregate throughput.

NVBU-13678 (30596)

Known issues related to DR Series Systems:

When performing a backup using the NetVault Backup Plug-in for VMware (Plug-in for VMware), if you set the client mode type to dedupe, the throughput is lower when compared with the passthrough mode. If you do not set the client mode on the DR Series system, the Plug-in for RDA automatically chooses the best mode for the backup.

 

On a Linux system, NetVault Backup fails to access a DR Series system if you do the following:

When you remove the plug-in, it deletes the directory /usr/local/oca-libs, which causes an error when NetVault Backup tries to access the device.

Workaround: After removing the plug-in, complete the following steps:

1
Ensure that the /usr/local/oca-libs directory has been removed. If not, remove the directory.

 

The Delete Non-Scheduled Jobs option is intended to delete unscheduled jobs after a specified period. Because the jobs using the Triggered schedule type have no physical scheduled time, they are also deleted after the specified period elapses. If you are using Triggered jobs in your NetVault Backup environment, do not use the Delete Non-Scheduled Jobs option.

 

When using NetVault Backup Plug-in for NDMP (Plug-in for NDMP), if you run multiple jobs with the auto-deletion option set to “On,” the parent and child jobs may still be listed on the Job Status page.

Workaround: To correct this issue, close the NetVault Backup WebUI, and start it again. There is no need to stop and restart the NetVault Backup Service.

 

The canned report “Disk Storage Devices — General” is intended for the NetVault SmartDisk devices; this report does not show details about the DR Series systems and Data Domain Systems.

 

After restoring the NetVault Database, when you restart the NetVault Backup Service, the job status shows “Scheduler Aborted Whilst Job Running.” This message can be ignored.

 

On a Solaris (SPARC or x86-64) system, when the LANG variable is set to en_US.UTF-8, the restore job wizard does not display the filenames on the Create Selection Set page. This issue is not encountered when LANG is set to C.

 

On Windows 2008 and Windows 7, if the OS firewalls are turned on, connectivity issues between the NetVault Backup Client and Server may be encountered occasionally even if the port exceptions have been correctly configured on the NetVault Backup Client. For more information, see https://support.quest.com/kb/SOL79286.

 

If the default locale is changed (for example, from UTF8 to EUC or from EUC to UTF8), the EULA may not be displayed properly.

Workaround: To view the EULA, use a terminal that can display EUC character set.

 

The Edit option on the Set Management page lets you select multiple backup sets while editing an existing set for a Data Copy backup job.

NVBU-14441 (31745)

Pre-configured reports, including Disk Storage Devices - General, Front Side Data, Storage Utilization, and Storage Utilization - RAS, did not report the correct value for Licensed Protected Capacity.

NVBU-14623

Job details are not displayed when you click a policy job in the Job Status widget on the NetVault Backup Dashboard page.

NVBU-17538

After running a job, when you go to the Job Status page to monitor the status of the job, it shows all the jobs with previously applied filters instead of showing all current activity.

Workaround: Select the Current Activity option in the View By job status filter option.

NVBU-17582

You cannot restore the data items of a network share backup located using the catalog search feature.

NVBU-17632

If you perform multi-stream backups to tape, select the Archive and Migration options in Backup Life, and identify an expiration date, the savesets are corrupted after the expiration is reached.

Workarounds:

NVBU-18297

When a LUN is mounted on an unsupported volume and the disk information is retrieved for a snapshot, the disk properties shows for VMware disk and not Huawei or Compellent disk. This causes the snapshot to fail.

NV-47, NV-49, (NVBU-18642, DNFSP-1016)

If you use parallel streams for a backup job that targets an individual tape library or VTL, one stream begins writing the data to the library, while the other stream waits. If you cancel the backup job, the stream that was waiting starts running. If you continue to cancel and re-run the backup job, the library eventually becomes full.

NVBU-18830

In specific instances, changing the time window in the server monitor from 8 hours to another time range then back to 8 hours results in an incorrect graph.

Workaround: Use the 12-hour or 24-hour setting.

NVBU-18975

The Unusable Media widget on the dashboard does not show media that must be recovered.

NVBU-19214

The error “duplicate key value violates unique constraint” message appears multiple times in the pg_sql log files.

NVBU-19246

For LTO-7 tapes, the Explore Storage page inaccurately displays the size of an unused tape.

NVBU-19250

When running a historic job report by date on a Japanese Standard Time server, not all information displays in the report.

NVBU-19313

The NetVault Backup - Supported VTLs, Libraries, Tape and Optical Drives document does not include the latest versions of DD Boost and DD OS supported by NetVault Backup after release 12.0. with “certification” information.

Workaround: This information is available in the Avamar, Data Domain, DDBEA, NetWorker and ProtectPoint Compatibility Guide on the Dell EMC website.

NVBU-19348

The Storage Utilization report shows the wrong licensed capacity for SmartDisk.

NVBU-19385

In a situation where you have one five-client license and one virtual client license, if five physical clients were added and you add one virtual client, then the virtual client addition shows as successful in the events list but does not appear under Manage Clients.

NVBU-19425

While choosing a default plug-in option after switching the language, the Web UI goes into deadlock, and performs no further operations.

NVBU-19427

When you try to reset the locale from French to English from the Server Change Setting page, the NetVault Backup Server goes into Safe Mode.

NVBU-19493

QoreStor does not support multi-tenancy.

QS-437, DNR3‑71

If you run parallel backup or restore jobs on an AIX client with a QoreStor target, the jobs fail with a “Job Manger has lost the message channel unexpected” error message.

QS-4252, DNR3-870

When the Broadcast details to machines on local networks setting is disabled on a client, the nvclient utility fails to add the client.

Workaround: Use the nvclientadd -clientip <Client IP address> command to add the client.

NVBU-12966 (28829)

The asf_load_media command fails if the machine name contains any spaces.

 

When the asf_release_drive command is issued to various brands of library devices (for example, those containing various Exabyte or 9840 drives), a delay of up to eight (8) minutes may occur before a piece of media is unloaded.

Workaround: The workaround is to issue the “Unload” command from the NetVault Backup WebUI.

1
In the Navigation pane, click Manage Devices, and then in the list of devices, click the applicable drive or the corresponding Manage Device icon.
2
On the Tape Drive Management page, click Unload.
The drive remains in and “Idle” state, and media are not unloaded as expected. If the logs for the selected device are viewed, an entry stating “Unload media in drive <X> failed — Device unavailable” is displayed. Repeat Step 2 to unload the media.

 

The range function does not work properly for the nvacslsmedia command.

Workaround: The workaround is to explicitly run this command for each media item that you want to allocate or deallocate. You can use a script to do this task.

 

When a space character is all that is specified for a library name with the nvcleandrive command, the first library on the Manage Devices page performs a clean operation on the specified drive. For example, if you run the command nvcleandrive libraryname “<space character only>” -librarydrivenumber <X>, NetVault Backup automatically targets the first library on the Manage Devices page and perform a clean operation on drive <X>.

 

When a null value is specified with the nvexpiresaveset command, any random saveset is expired.

 

When you run the nvjobmodify command, the job is submitted to run, even if you do not include the “‑submit” option in the syntax.

 

When a null string is specified with the nvremovemedia command, the first entry is deleted from the Media Database.

 

The nvsetcleaninglives command does not report any errors if you configure incorrect values for the lives option.

 

The “-include” option for nvsetcreate cannot be used to specify data selections below the “Fixed Drives” node in the selection tree.

 

The nvsetmodify command cannot be used to modify Schedule Sets. You can create a set using nvsetcreate, and assign it the same name to overwrite the existing set.

 

On Windows-based installations, the nvsyncronizesilomedia command does not update the media status on the Manage Devices page.

 

Table 6. Plug-in for FileSystem known issues

On Snap Appliance Filers, data must only be relocated to existing directories. Items relocated to directories that do not exist cannot be accessed due to permissions settings on the newly created directories.

DNFSP-113 (13979, (FSG‑188)

On ZFS, if the backup data contains ACLs on extended attributes, the restore job fails when you use the default restore options. If errors occur on restore of metadata, select the Discard Metadata option to restore the data.

DNFSP-456 (14324, (FSG‑514)

The IIS Metabase node in the System State tree is not visible by default on Windows Vista, Windows 7, and Windows 2008 systems. To enable this node, install the IIS 6 compatibility pack, or create a selection set that includes the IIS config and schema files located under %windir%\system32\inetsrv\config.

DNFSP-508 (14376, FSG‑563)

On Solaris ZFS and UFS file systems, the files and directories for which only the extended attributes have changed do not qualify for Incremental Backups.

DNFSP-636 (14504, FSG‑684)

When restoring a Linux or UNIX backup to a Windows-based NetVault Backup Client, the items are restored successfully, but the job generates the following warning and log context:

Log message: <num> items and their contents could not be restored

Log context: <filename>: writing to file: Incorrect function

These messages can be ignored.

DNFSP-718 (14586, FSG‑760)

NetVault Backup does not allow Apple Xsan restores when there are no affinity tags on the target server.

DNFSP-727 (14596, FSG‑770)

The exclusion list is not enforced for a corrupt file in an Incremental Backup.

DNFSP-910

On Oracle Solaris hosts, enabling a multi-stream FileSystem backup causes Incremental Backup performance to appear similar or worse than a Full Backup.

DNFSP-921

If the name of a network share folder includes Japanese characters, NetVault Backup does not add it.

DNFSP-932

The FileSystem backup and restore job fails to write an entry into the log file when the Path to Backup log and Path to Restore log options are selected.

DNFSP-991

On Windows 2008 and Windows 2003, the System State node does not include the Removable Storage Manager Database node.

 

The Verify After Backup option does not work for a restarted job instance.

 

When you submit a policy job created for a UNIX file system on a Windows system, the job status shows “Completed with Warnings,” but no data is backed up.

 

The following known issues apply to the Backup Windows File Short Names and Restore Windows File Short Names options:

 

Although VSS backups complete successfully, the message “Error deleting volume snapshot(s): VSS_E_BAD_STATE” is written to the NetVault Backup logs.

 

If a job restores a Windows symbolic link (file created using mklink, not Windows shortcut), where the symbolic link file exists on the target file system and the data file the symbolic link targets also exists, the data in the targeted data file is lost. Ensure that the data files targeted by symbolic links are included in backups. Quest recommends that you delete the existing symbolic links that you want to restore from the target file system before running a restore job. To avoid any risks of data loss, you can also perform backup of data files possibly at risk before running the restore job.

 

When a symbolic link is restored, GuardianOS applies the Xattr attribute user.SnACL to it. This behavior is expected and does not have any negative effects.

 

Backups on GFS and GFS2 can stop responding if the files or directories are frozen.

 

In an environment with many direct automounts on Solaris Clients, a backup job may remain at “Waiting for Job Options” status while the Plug-in for FileSystem attempts to load the automounts temporarily to determine whether they are on remote systems. This delay can be alleviated by selecting the “Backup through Remote Mounts” option. If necessary, clear or exclude remote mounts or add the following stanza to the file nvfs.cfg:

[Performance:DoRecursiveAutoMountScan]

Value=FALSE

 

Restore operation of multi-volume selection for an offhost backup fails after successful off-host backup for multi-volume selection.

NV-48 (NVBU‑18349)

The nvreport utility does not work in the MSP environment.

NVBU-18346

System requirements

Platform

For complete supported platform information, see the Quest NetVault Backup Compatibility Guide available at https://support.quest.com/technical-documents.

Memory

Memory requirements on a target system can vary based on the intended use.

Hard disk space

A NetVault Backup server installation requires about 800 MB of disk space on Windows-based systems and 800 MB of disk space on Linux-based systems.

Operating system

NetVault Backup Server

The server can be installed on the following operating systems:

NetVault Backup Client

The client can be installed on the following operating systems:

For more information, see the Quest NetVault Backup Compatibility Guide available at https://support.quest.com/technical-documents.

Web browser

The NetVault Backup WebUI supports the following browsers:

Upgrade and compatibility

NetVault Backup Server OS requirements: The NetVault Backup Server installation is supported on Windows and Linux operating systems. The NetVault Backup Server installation is not supported on Mac OS X and UNIX operating systems. For information about supported operating system versions, see the Quest NetVault Backup Compatibility Guide available at https://support.quest.com/technical-documents. For information on migrating NetVault Backup Server 9.2 from Mac OS X or UNIX to Windows or Linux, see https://support.quest.com/kb/SOL126805.
NetVault Database migration: Upgrade from 9.2 involves the migration of NetVault Database from proprietary format to the PostgreSQL database. The migration can take a significant amount of time depending on the size of your NetVault Database and other factors such as system performance.
Select the correct installation package on Linux and Windows: NetVault Backup offers separate client‑only and server-only installation packages for Linux- and Windows-based systems. Both the server and the client packages are available in hybrid and pure 64-bit versions:
Hybrid server and client packages: The hybrid packages are intended for users who do not have a pure 64-bit-only requirement.
Pure 64-bit server and client packages: The pure 64-bit packages are intended for pure 64-bit operating systems. If you have a specific reason that you cannot use any 32-bit components (for example, you are using a Linux distribution that does not run 32-bit code), use these packages.
netvault-<RYYYYMMMDD>-vx.x.x.x-Server-{LinuxX86Hybrid|WindowsX86Hybrid}: Use this package to install or upgrade NetVault Backup Server on 32-bit or 64-bit systems.
netvault-<RYYYYMMMDD>-vx.x.x.x-Server-{LinuxX86Pure64|WindowsX86Pure64}: Use this package to install or upgrade NetVault Backup Server on pure 64-bit systems.
IMPORTANT: Before installing the hybrid package of NetVault Backup on 64-bit Linux machines, ensure that all the required 32-bit libraries are installed on the system. For more information about the requirements, see the Quest NetVault Backup Installation Guide. The installation process may fail silently if the installer is unable to find the required libraries on the system.
Table 9. Pure64 builds

32-bit

32-bit

X

 

X

 

 

Hybrid

X

 

X

 

 

64-bit

Itanium

 

 

 

X

 

64-bit

 

X

X

 

 

Hybrid

X

X

X

 

 

Pure64

 

 

 

 

X

Licensed plug-ins: After upgrading to the latest version of NetVault Backup, you may be unable to create new backup jobs with previously installed licensed plug-ins. This issue occurs in the following upgrade scenarios:
SNMP Trap Notification Object Identifier (OID): After you upgrade from NetVault Backup 9.2, the OID for the SNMP Trap Notification method is changed.
NetVault Backup Plug-in for NetWare (Plug-in for NetWare): NetVault Backup 10.0 and later do not support Plug-in for NetWare.
Plug-in for VMware and NetVault Backup Plug-in for Hyper-V (Plug-in for Hyper-V): After installing the Plug‑in for VMware or Plug-in for Hyper-V, if you upgrade the NetVault Backup software, you must re‑install the plug-in on that machine. If you do not reinstall the plug-ins, you cannot open the Drives node of a mounted virtual machine to create any new file‑level backup jobs.
Device names containing multibyte characters: After upgrading from NetVault Backup Server 9.2, a device that uses multibyte characters in its name must be removed and added again.
Documentos relacionados

The document was helpful.

Selecione a classificação

I easily found the information I needed.

Selecione a classificação