Clearing Alarms

To automate the clearing of future dated alarms, the registry variable, Auto_Clear_Integration_Alarms_with_EndTime, can be changed. The default value is false. When true, the alarm with a user-defined end time is cleared automatically when the alarm is first received. When set to false, any alarm with a user-defined end time is not cleared in that manner. Otherwise, these must cleared using the user interface or by using the new Clear Integration Alarm Rule. This new rule is disabled by default. When enabled, this rule runs every five minutes. This rule looks for third-party alarms with an end time in the past that have not been cleared, and then clears the alarm. This keeps the alarm in the browser until the end time is reached.
1
On the navigation panel, under Dashboards, click Administration > Rules and Notifications > Manage Registry Variables.
2
Click Auto_Clear_Integration_Alarms_with_EndTime.
For more information on how to edit registry variables, see the Foglight Administration and Configuration Guide.

Processing Alarms

Table 2. Alarms

Working with Configuration Items

NOTE: In a federated environment, it is important to keep CI Properties consistent between federated Management Servers. For example, if one federated Management Server has a property called External asset id that is a type of Integer and Is List, other federated servers should have a property called External asset id that is a type of Integer and Is List. CI Properties must be consistent across federated servers.

Reviewing the Property Details of a Configuration Item

Documentos relacionados

The document was helpful.

Selecione a classificação

I easily found the information I needed.

Selecione a classificação