Replication fails with "Specified argument was out of the range of valid values"
Descrição
After an upgrade or a clean install of Rapid Recovery 6 replication fails with the following error:
Exception chain:
Specified argument was out of the range of valid values. Parameter name: One or more of the read buffers are not large enough for the number of records being read
One or more errors occurred.
Causa
This issue is caused by a large amount of data trying to replicate.
Resolução
To resolve the issue change the Volume Image Session Timeout on both cores to 60 minutes.
This setting is located under Replication tab -> Settings (icon that looks like a gear).
Restart the core services after making the changes.
Your Request will be reviewed by our technical reviewer team and, if approved, will be added as a Topic in our Knowledgebase.
Conteúdo recomendado
Produto(s):
Rapid Recovery
6.0.1
Tópico(s):
Troubleshooting
Histórico do artigo:
Criado em: 3/30/2016 Última atualização em: 5/7/2023
Thank you for your feedback for Topic Request
Your Request will be reviewed by our technical reviewer team and, if approved, will be added as a Topic in our Knowledgebase.
Bem-vindo ao Suporte
Você pode encontrar ajuda de suporte on-line para *produto* da Quest em um local de suporte afiliado. Clique em Continue (Continuar) para ser direcionado ao conteúdo de suporte correto e à assistência a *produto*.
Search All Articles
Encerramento do suporte aos navegadores IE 8, 9 e 10
O Portal da Quest Software não é mais compatível com IE8, 9 e 10. Recomendamos a atualização do navegador para a versão mais recente do Internet Explorer ou do Chrome.