Chatee ahora con Soporte
Chat con el soporte

Spotlight on Oracle 10.5 - Getting Started Guide

Welcome to Spotlight Install Spotlight Start Spotlight Spotlight on Oracle Spotlight on Oracle Data Guard Spotlight on Oracle RAC Spotlight on Unix Spotlight on Windows Spotlight on MySQL Troubleshooting: Connection Problems

Cell Balance Alarm (Exadata)

The Cell Balance alarm is raised when there is an unequal distribution of work-load between the Exadata Storage Servers (Cells).

The source of this alarm could be:

  • A new Exadata Storage Server (Cell) has been added, or an existing Cell has been restarted.
  • An Exadata Storage Server (Cell) has failed.
  • Services have failed on an Exadata Storage Server (Cell).

 

Actions to take:

  • Rectify any hardware problems.
  • Check the management services on the Exadata Storage Servers (Cells).

 

The balance metric is based on total reads and writes for each cell. To determine whether there is an unequal distribution of work-load the Kruskal-Wallis Non Parametric test (to a 95% probability) is applied to the 30 most recent historical values. For installations where there are two Exadata Storage Servers the Mann-Whitney U test is used.

 

Documentos relacionados

The document was helpful.

Seleccionar calificación

I easily found the information I needed.

Seleccionar calificación