Release Notes
June 2017
These release notes provide information about the Spotlight® on Oracle release.
Topics:
Spotlight is a powerful diagnostic and resolution tool for Oracle databases. Its unique user interface provides you with an intuitive, visual representation of the activity on your database. Graphical flows illustrate the rate at which data is moving between database components. Icons display the value of key statistics and metrics.
Spotlight on Oracle is used to diagnose the performance of Oracle instances running on individual host machines. It also includes the following products:
Spotlight on Oracle RAC requires additional licensing. It enables the diagnosis of Oracle databases on multiple host machines under the Real Application Clusters (RAC) architecture and additionally may include monitoring of Exadata systems depending on the license purchased.
Spotlight on Oracle 10.4
Spotlight on Oracle 10.4 is a maintenance release with no new functionality.
Spotlight on Oracle 10.3.3
Spotlight on Oracle 10.3.3 is a maintenance release with no new functionality.
Spotlight on Oracle 10.3.2
Spotlight on Oracle 10.3.2 is a maintenance release with no new functionality.
Spotlight on Oracle 10.3.1
Windows 10: Windows 10 is a supported platform for the installation of Spotlight on Oracle and the Spotlight Diagnostic Server, and for monitoring.
Spotlight on Oracle 10.3
In-Memory Diagnostics: Spotlight now provides diagnostic information for In-Memory databases in Oracle and Oracle RAC. What is the cost to the database of enabling In-Memory? Has the right amount of memory been allocated to the In-Memory column store? To what extent is I/O being consumed by In-Memory activities? Drilldown further by segments, SQL, statistics and sessions.
The following is a list of issues addressed and enhancements implemented in this release.
Area | Resolved Issue | Defect ID |
---|---|---|
Installation | Dependency on .Net 3.5 is now removed. Spotlight on Oracle is now dependent on .Net 4.0 or above. | SOO-2421 |
Monitoring | Spotlight on Oracle supports monitoring of Oracle 12.2. | SOO-2605 |
Alarms | Corrected a problem where the Array Fetch Alarms were raised when the Spotlight User was the only connected user to the database. | SOO-2592 |
On adding an alarm action to send an email when the alarm is raised, the content of the email has been cleaned of special characters making it much easier to read. |
SOO-2618 | |
Creating a connection |
Corrected a problem where click "View information about objects installed and privileges required by Spotlight " when creating an Oracle RAC connection with a new user resulted in an unexpected error. |
SOO-2560 |
General | Corrected problem causing unexpected error with message: Assertion failure (E:\Jenkins\jobs\SoO Nightly Build - from GIT\workspace\Spotlight\Source\MDK\components\SpotlightGraphics.pas, line 348) | SOO-2610 |
The following is a list of issues addressed and enhancements implemented in 10.3.3.
Area | Resolved Issue | Defect ID |
---|---|---|
Browse History | Corrected the source of an unexpected error (Interface not supported) when using the History Browser. | 2557 |
Spotlight user creation script | References to the QUEST_LUCY_COLLECTOR package have been removed from the Spotlight user creation script for Oracle 11gR2 and above. | 2569 |
Removed code involving the SYS obects (SYS.EXECUTE_IMMEDIATE and SYS.BUILD_XVIEW) from the Spotlight user creation script for Oracle 11gR2 and above. |
2568 |
The following is a list of issues addressed and enhancements implemented in 10.3.2.
Area | Resolved Issue | Defect ID |
---|---|---|
Spotlight Essentials | Corrected a problem on sign in to Spotlight Essentials from the Spotlight on Oracle client through a proxy server. | 2272 |
Tablespace Utilization drilldown | Corrected the source of an unexpected error ("Range check error") on the Disk Storage | Tablespace utilization drilldown. | 2481 |
General | Corrected the source of unexpected errors ("Integer overflow" Source 02041D9D) when using Spotlight functionality using a periodic timer like the slideshow. | 2488 |
Monitoring Unix Connections |
Corrected a problem where the memory value display was incorrect on the Spotlight on Unix home page for some Unix connections. This issue was related to Linux bug https://bugzilla.redhat.com/show_bug.cgi?id=1246379 |
2516 |
Top Sessions |
Corrected Overflow error in Top session drilldown. |
2510 |
Predictive Diagnostics | Corrected a problem where Predictive Diagnostics charts displayed no data. | 2517 |
Spotlight charts | Corrected a problem with the zoom functionality in Spotlight charts. | 2524 |
The following is a list of issues addressed and enhancements implemented in 10.3.1.
Area | Resolved Issue | Defect ID |
---|---|---|
Monitoring UNIX connections | Fixed a problem where no data was displayed for Disk Reads and Disk Writes when monitoring a Unix connection, AIX 7.1 server. | 2433 |
Monitoring Oracle connections | Fixed a problem on the Tuning | Memory Management drilldown page where Total Oracle Memory failed to accept a 6 digit number. | 2434 |
Fixed a problem on the Configuration & Memory | Buffer Cache drilldown page where no data was displayed in the buffer cache details grid when a non-default pool was selected. | 2437 | |
General | Resolved "Integer Overview" issue. | 2430 |
The following is a list of issues addressed and enhancements implemented in 10.3.
Area | Resolved Issue | Defect ID |
---|---|---|
Slideshow | You can now configure the Slideshow to remain active through mouse or keyboard activity. | 2300 |
Licensing | Spotlight on Oracle can now accept licensing per monitored instance. | 2323 |
Spotlight Web Publisher | The Spotlight Web Publisher is now merged into the Spotlight Diagnostic Server. In previous releases of Spotlight on Oracle the Spotlight Diagnostic Server and Web Publisher were both required to use Spotlight Mobile. Now only the Spotlight Diagnostic Server is required. On upgrade to Spotlight on Oracle 10.3 the Spotlight Web Publisher will be removed automatically. | 2355 |
Unexpected Area | Fixed a problem where an Unexpected Error | Integer Overflow occurred on resizing a drilldown window. | 2296 |
Monitoring Oracle connections | On the Alert Log drilldown fixed error ORA 01426: numeric overflow. The Log viewer can open files up to 2Gb in size. | 2309 |
Top Sessions | Fixed the source of the following error on the Top Sessions drilldown: "Duplicates not allowed in table TopSessionsWithoutEvent". | 2354 |
Monitoring Oracle Data Guard | Fixed issues connecting to a Data Guard Standby database in environments with fast connections. | 2326 |
Monitoring Exadata | Fixed a problem where Spotlight is incorrectly derived the cell port number from the subnet mask. | 2290 |
Monitoring Unix | Fixed a problem where Spotlight could not connect to Red Hat 7. | 2291 |
Oracle 9i is no longer supported.
Windows Server 2003 is no longer a supported operating system.
Spotlight on Oracle is no longer localized into Chinese.