When working with an IAM Role authenticated EC2 Instance and <strong>IMDSv2</strong> set<strong> </strong>to <strong>Required</strong>:<br> ... <p style="text-align: center;"><strong><img src="https://prod-support-images-cfm.s3.amazonaws.com/KB_kA06R000000HLYbSAO_003.png"></img></strong></p>
When restoring a backup made in Litespeed, from a mapped network drive (e.g. ... Y:\), it hangs at 0% and never completes.<br>There is no job failure in the Litespeed Activity window though, and no errors in the Event Viewer.
When you kill the SQL Server spid for a LiteSpeed backup/restore process, the spid may go into a killed\rollback state which may process slowly or hang. ... Then kill the spid in SQL Server. ... If that does not resolve, restart the sql server service.
How to create a LiteSpeed support bundle? ... RDP to the machine that you would like to create the support bundle, then launch LiteSpeed console. ... Under the Backup Manager tab, highlight the local instance.
The following error appears when trying to restore from a cloud location:<br><br>'Failed to execute operation LiteSpeed restore for database DatabaseName.<br>Message Unexpected termination on thread: 0, Return code: x80770004<br><br>The media family on device LiteSpeed® for SQL Server® backup file is incorrectly formed. SQL Server cannot process this media family.'<br><br>It fails with random transaction logs, This issue may occur with SQL Server 2019 with CU13 installed Please upgrade SQL Server to CU16 or above (the latest for SQL Server 2019 CU is CU19) and after upgrading perform again the steps to check if the issue is fixed
In order to use @OLRMAP=1, the sql server user will need to have read/write access to the cluster service users temp directory. ... <p>On a cluster, the temp directory returned from theOperating Systemis the temp directory of the user that is running the cluster service, which will be %USERPROFILE%\Local Settings\Temp.<br><br>Resolution:<br>1.
<div>How to query multiple servers for LiteSpeed information? ... Is there a built in feature to gather information regarding the LiteSpeed application?</div> <div>LiteSpeed does not have a built-in function to query multiple servers for LiteSpeed application information at the same time.
Please check the version of LiteSpeed Logshipping in the LSOption table of the LiteSpeedLocal table on both the Publisher and Subscriber(s). ... In query analyzer: use LiteSpeedLocal go select LSVersion from LSOptions
Does the LiteSpeed Activation key change after an upgrade of SQL Server and re-install LiteSpeed.? ... New license key is not required. ... It is advised that the LiteSpeed be uninstalled prior to the SQL Server update and reinstalled when the new version of SQL Server is running.
Make sure the SQL Server Service Account and the SQL Server Agent Service Account are run under the same domain account and have permission on the both the Publisher and Subscriber servers. ... The accounts must be able (have the right) to access the other master and msdb database, to call system procedures, to create jobs and have full permission to access LiteSpeedLocal Database.
Full error message: The backup database has on-disk structure backup version 611. ... The server supports version 539 and cannot restore or upgrade this database. ... This error occurs when restoring SQL Server 2005 backup to SQL Server 2000.
Datetime punch and delete old backups capabilities is not avaliable in xp_backup_database.</p>
Central repository was moved to another server or instance. ... However, prior moving the repository, it was not deleted from Enterprise Console. ... When attempting to delete and add new central repository in Enterprise Console, the old central repository will not delete.
Partial backups are new in SQL Server 2005. ... Description from Microsoft Books Online: A partial backup is similar to a full backup, but a partial backup does not contain all of the file groups.
When doing a restore, the following error is displayed: The log in this backup set cannot be applied because it is on a recovery path inconsistent with the database ... This is not a LiteSpeed Error.
Upgrade Advisor analyzes instances of SQL Server 7.0, SQL Server 2000 and SQL Server 2005 to help prepare for upgrades to SQL Server 2005/2008. ... Running this may detect certain LiteSpeed objects as not compatible with SQL Server 2005/2008.
We can use LiteSpeed console Restore Wizard to manually restore a database full backup file and tlog files. ... However, when we use the Restore Wizard to do an 'Automated restore' on those same files in that same directory, LiteSpeed does not recognize the backup files.
When trying to restore backup to and instance with non-default port the following error appear: VDI open failed due to request abort error:61700. ... Update to the latest version of LiteSpeed.
On one of our servers we are backing up multiple databases and some but not all are getting a full backup created every time no matter whether it is a full, differential or transaction log backup specified in the Maintenance Plan 'Back up Database' task.<br><br>It seems to be because we have selected the option to “Force a full backup if one has not been created" in our Maintenance Plans (MPs).
We are looking to patch our Litespeed Central Repository SQL Server to the next Service Pack level and wanted to know if there are any precautions or steps that are needed to do this? <p>There's no concerns/precautions/steps needed with this regarding LiteSpeed.
We see that the automated restore process requires a FULL and will not work with a directory that just contains the subsequent tlogs. ... If so, what would I give our clients/customers to use to restore subsequent log files automatically on a specified schedule?
Automated restore fails with error "not a valid pathname in directory" when database/index with a filestream filegroup in it. ... <div>When automated restore is used to restore a database/indes with a filestream filegroup in it.
This will show any failed jobs and suggested next steps. ... EXAMPLE: ... You can also review the jobs that make up the plan on the job manager page. ... EXAMPLE: (right click the log shipping plan and select “display jobs”)
To generate a LiteSpeed Enterprise Console log for purposes of troubleshooting from the LiteSpeed Enterprise Console in Version 5.x + ... Console logging is enabled in the console by: 1. ... Click the tools menu and choose options.
Error received when attempting to run a back up: ... "The process cannot access the file because it is being used by another process". ... This issue may occur if antivirus software is running in the same location of the backup file or mutliple jobs may be simultaneously scheduled to backup the same database.
© ALL RIGHTS RESERVED. Términos de uso Privacidad Cookie Preference Center