지금 지원 담당자와 채팅
지원 담당자와 채팅

DR Series Software 4.0.3.1 - Command Line Reference Guide

Introduction to the DR Series System Command Line Reference Guide Introducing the DR Series system Managing the DR Series system
Alerts Commands Authenticate Commands Network
Network Command Usage network --show network --delete network --restart network --setdhcp network --setstatic_ip [--bondif <bondN>] [--nwif <ethN>] --ip <IPv4/IPv6 address not already in use> --netmask <netmask> [--gateway <IPv4/IPv6 address>] network --create_bond network --create_eth network --add_member network --setdns [--suffix <dns suffix>] [--primary <IPv4/IPv6 address>] [--secondary <IPv4/IPv6 address>] network --setbonding --bondif <bondN> [--mode <ALB | 802.3ad>] [--mtu <supported MTU range 512 - 9000>] network --update network --factory_reset network --host network --route network --nslookup --destination <ip address | hostname> network --traceroute --destination <ip address | hostname> network --ping --destination <ip address | hostname> [--tries <number>] [--size <number>] [--interface <bondN | ethN>] network --blink network --enable network --troubleshoot [--links] [--gateway] [--ntp] [--dns] [--active_domain] [--nis] [--clients] [--port_mapper] [--network_config] [--show_active <NFS|CIFS|OST|RDS|NDMP|ISCSI|FC>] [--interface <bondN | ethN>] network --troubleshoot --gateway --interface <bondN | ethN> network --troubleshoot [--show_active <NFS| CIFS|OST|NDMP|ISCSI|RDS>] network --tcpdump [--port <nfs | windows | replication | ost | rds>] [--pkt_size <128 - 32768>] [--file_size <0 - 100>] [--stop] [--host <ip address list>] [--interface <bondN | ethN>] network --tcpdump [--pkt_size <128 - 32768>] network --tcpdump [--file_size <0 - 100>] network --tcpdump [--host <ip address list>] network --tcpdump [--port <nfs | windows | replication | ost | rds>] network --iperf_client --server <ip address | hostname> [--port <number>] [--window_size <num bytes [KB/MB]>] [--interval <num seconds>] [--time <num seconds>] network --iperf_server [--port <number>] [--window_size <num bytes [KB/MB>] network --help
OST RDA Stats Storage Group commands System
System Command Usage system --show [--config] system --show [--hardware] system --show [--storage] [--type <boot | internal | external>] [--service_tag <service tag>] system --show [--storage] system --show [--license] [--verbose] system --show [--ntp] system --show [--version] system --show [--timezones [Region]] system --show [--upgradefile] system --show [--upgradehistory] system --show [--marker] system --show [--replication_traffic] system --show [--opdup_traffic] system --show [--backup_traffic] system --show [--mgmt_traffic] system --init system --init --secure_erase <1–pass/3-passes/7-passes> system --reboot system --shutdown system --upgrade system --license [--validate] [--add] system --setname --name <node_name> system --setdate [--date <date>] [--timezone <Region/Zone>] system --setntp [--add <server name>] system --setntp [--delete <server name>] system --setntp [--enable] system --setntp [--disable] system --setntp [--adjust_time] system --hybrid_replication [--enable][--disable][--status] system --rdairgap [--enable][--disable][--set_retention_period <0 days to 365 days>][--get_retention_period][--open][--close][--status] system --rdairgap_schedule [--start_time <HH:MM>][--end_time <HH:MM>][--remove] system --setlogin system --telnet [--enable | --disable] system --datacheck --enable system --datacheck --disable system --datacheck --throttle system --marker [--enable] [--disable] system --verify_on_read [--enable] [--disable] system --add_storage --enclosure <service tag> system --storage [--set_usage_alert <70% - 90%>] system --storage [--blink] [--type <internal | external>] [--service_tag <service tag>] [--disk <slot num>] system --storage [--unblink] [--type <internal | external>] [--service_tag <service tag>] [--disk <slot num> system --mgmt_traffic system --backup_traffic system --replication_traffic system --opdup_traffic system --help
User Virtual Machine
Maintaining the DR Series System
Diagnostics Maintenance
Maintenance Command Usage maintenance --filesystem [--start_scan [verify_data | verify_rda_metadata | verify_metadata] [--storage_group <name>] maintenance --filesystem [--stop_scan] maintenance --filesystem [--scan_status] maintenance --filesystem [--scan_report [verbose]] maintenance --filesystem [--repair_status [verbose]] maintenance --filesystem [--repair_history [verbose]] maintenance --filesystem [--scan_restart [verify_data | verify_rda_metadata | verify_metadata]] maintenance --filesystem [--repair_now] maintenance --filesystem [--reclaim_space] maintenance --filesystem [--clear_quarantine] maintenance --filesystem [--clear_quarantine] maintenance --filesystem --show_throughput maintenance --configuration [--backup] maintenance --configuration [--restore] maintenance --configuration [--reinit_dictionary] maintenance --configuration [--reset_web_certificate] maintenance --configuration --enable_sha256_web_certificate maintenance --hardware [--reinit_nvram] maintenance --hardware [--restore_hw_db] maintenance --hardware [--motherboard_replaced] maintenance --disk [--make_standby [slot num]] [--type <internal | external-<num> | service tag>] --clear_foreign] maintenance --remote_access [--show] maintenance --remote_access [--enable] maintenance --remote_access [--racreset] maintenance --remote_access [--static_ip] [--ip <IPv4/IPv6 address>] [--netmask <netmask>] [--gateway <IPv4/IPv6 address>] [--device <lom1|lom2|lom3|lom4>] maintenance --remote access [--disable] maintenance --vdisk --check_consistency --type <boot|internal|external> [--service_tag <service tag>] maintenance --help
Managing DR Series System Storage Operations
System Storage Operation Commands Connection Container VTL NDMP iSCSI FC Replication Seed Schedule
Data Integrity Checking Additional Linux Commands About us

network --add_member

Description

Syntax

For example, to add eth2 to bond1, run the command: network --add_member --bondif bond1 --nwif eth2

Result

network --setdns [--suffix <dns suffix>] [--primary <IPv4/IPv6 address>] [--secondary <IPv4/IPv6 address>]

Description

Configures the domain name system (DNS) for a DR Series system, which includes the corresponding DNS suffix and a primary name server IP address (and optionally, a secondary name server IP address).

Syntax

network --setbonding --bondif <bondN> [--mode <ALB | 802.3ad>] [--mtu <supported MTU range 512 - 9000>]

Description

Configures or updates the bonding mode or sets the maximum transmission unit (MTU) number to use for a DR Series system.

Syntax

Result

NOTE: When using the DR Series system CLI --setbonding and --mtu commands, a warning dialog displays with the following message:
Incorrectly setting the MTU size will cause the DR4000 to not respond. You will
need to log in to the system console and use the
network --setbonding --bondif bond0 --mtu 1500 command
to resolve the issue. Please verify that the switch is enabled and capable of supporting an MTU size
that is equal to or larger than the value being set. Do you want to continue (yes/no) ?

In computer networking, jumbo frames are Ethernet frames with more than 1500 bytes of payload (but in some cases, jumbo frames can carry up to 9000 bytes of payload).

Many Gigabit Ethernet switches and Gigabit Ethernet network interface cards support jumbo frames. Some Fast Ethernet switches and Fast Ethernet network interface cards (NICs) also support jumbo frames.

Some computer manufacturers use 9000 bytes as the conventional limit for jumbo frame sizes. Internet Protocol (IP) subnetworks require that all hosts in a subnet have an identical MTU.

Consequently, interfaces that use a standard frame size and those that use a jumbo frame size should not be in the same subnet. To reduce the chance of interoperability issues, NICs capable of jumbo frames require special configurations to use jumbo frames. For more information, contact your Technical Support representative for assistance.

To verify that the destination system can support a specific frame size you want to attempt, use the following DR Series system CLI commands and specify the frame size in bytes using the following command as an example:

network --update

Description

Syntax

For example, to update bond1 to use a different MTU parameter, run the command: network --update --bondif bond1 --mtu 5000

Result

관련 문서

The document was helpful.

평가 결과 선택

I easily found the information I needed.

평가 결과 선택