Submitting forms on the support site are temporary unavailable for schedule maintenance. If you need immediate assistance please contact technical support. We apologize for the inconvenience.
An error has occurred while processing PictureBox 'image2'
설명
When running a report it returns this error message
An error has occurred while processing PictureBox 'image2': Invalid image data. ------------- InnerException ------------- The remote server returned an error: (401) Unauthorized.
해결 방안
To resolve please follow this steps
1. Open the ControlPoint Configuration Site | ControlPoint Settings List.
2. Click the Items tab | New Item.
3. Use the following details:
Parameter Name: TELERIKOVERRIDEIMAGE
Parameter Value: true
Title: Special-Purpose
4. Save then recycle the ControlPoint application pool.
5. Relaunch ControlPoint then run the report again to test resolution.