Submitting forms on the support site are temporary unavailable for schedule maintenance. If you need immediate assistance please contact technical support. We apologize for the inconvenience.
An error has occurred while processing PictureBox 'image2'
Description
When running a report it returns this error message
An error has occurred while processing PictureBox 'image2': Invalid image data. ------------- InnerException ------------- The remote server returned an error: (401) Unauthorized.
Resolution
To resolve please follow this steps
1. Open the ControlPoint Configuration Site | ControlPoint Settings List.
2. Click the Items tab | New Item.
3. Use the following details:
Parameter Name: TELERIKOVERRIDEIMAGE
Parameter Value: true
Title: Special-Purpose
4. Save then recycle the ControlPoint application pool.
5. Relaunch ControlPoint then run the report again to test resolution.
Your Request will be reviewed by our technical reviewer team and, if approved, will be added as a Topic in our Knowledgebase.
Recommended Content
Product(s):
ControlPoint
Topic(s):
Troubleshooting
Article History:
Created on: 3/15/2019 Last Update on: 5/7/2023
Thank you for your feedback for Topic Request
Your Request will be reviewed by our technical reviewer team and, if approved, will be added as a Topic in our Knowledgebase.
Welcome to Quest Support
You can find online support help for Quest *product* on an affiliate support site. Click continue to be directed to the correct support content and assistance for *product*.
Search All Articles
IE 8, 9, & 10 No longer supported
The Quest Software Portal no longer supports IE8, 9, & 10 and it is recommended to upgrade your browser to the latest version of Internet Explorer or Chrome.