By default, ControlPoint Discovery processes up to two site collections/sites simultaneously, for improved performance over sequential processing. For actions and reports, sequential processing is used by default (that is, the objects involved (site collection, site, subsite, lists, and so on) are processed one at a time, in hierarchical order). ControlPoint Application Administrators may, however, choose to
·increase or decrease the maximum number of objects that should be processed simultaneously (i.e., in parallel), and/or
·specify the operation(s) (Actions, and/or Reports) for which parallel processing should/should not be used.
Specify the operations for which parallel processing should be used by completing the Value of the ControlPoint Setting ParallelProcs with one or more of the following values:
·A (Actions)
·R (Reports)
Enter multiple values as a comma-separated list.
For this setting to be operational, the Value of the setting Maximum Number of Objects to Processed in Parallel.
By default, when Maximum Number of Objects to Process in Parallel is set to a value greater than 1, ControlPoint processes operations in parallel at the site collection level. ControlPoint Application Administrators can, however, have parallel operations processed at the site level by changing the Value of the ControlPoint Setting Objects Subject to Parallel Processing from false to true.
NOTE: This is an Advanced Setting.
By default, the ControlPoint SQL Command timeout value is set to 300 seconds. This value represents the amount of time that ControlPoint will wait for a SQL command to run before issuing the following message:
[Method Name]Timeout Exception: The server has timed out.
The default value should be sufficient in most cases. However, for an exceptionally large or busy farm, the ControlPoint Application Administrator may need to increase the Value of the ControlPoint Setting SQL Command Timeout Value.
NOTE: This is an Advanced Setting.
NOTE: Remember, this value is specified in seconds.
By default, when a ControlPoint user wants to initiate an operation from search or data analysis results, an unlimited number of SharePoint sites can be added to the Selection Builder.
A large number of objects passed to the Selection Builder may, however, significantly drain system resources. ControlPoint Application Administrators can limit the number of sites that are added to the SelectionBuilder by changing the Value of the ControlPoint Setting Maximum Number of Objects to Pass to Selection Builder. (Note that 0 is used as the default value to represent "unlimited.")
If the specified number is met, no additional sites will be added to the Selection Builder and the user will be presented with a warning message.
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. Termini di utilizzo Privacy Cookie Preference Center