To connect to a Windows machine as a user who is already logged in, do NOT enter any user credentials (Domain, User or Password) in the Connection Properties window.
Notes:
Windows connections can only have one set of credentials in use at a time. If a user connects to a machine by using NO user name and password, and then disconnects and reconnects with an Administrator password, Windows returns an ERROR_SESSION_CREDENTIAL_CONFLICT error.
For example, if you have mapped a drive to the machine \\serverA\share while logged in as serverA\administrator, you CANNOT map another drive to the same machine while logged in as serverA\user.
You can, however, connect to the same machine with different credentials if you map to the machine via its IP address.
In the example above, if serverA has the IP address 192.168.1.100, you CAN employ the net use command to connect to the machine \\192.168.1.100\share as serverA\user.
If Spotlight on Windows is displaying a WMI access denied error, and the user specified in the connection profile is an administrator on that machine then it may be necessary to adjust your DCOM or Firewall settings.
Complete the following steps to ensure that your DCOM and Firewall settings are configured to allow WMI connections.
To test WMI is working on the Spotlight client:
To check the DCOM access permissions for the monitored machine:
Under Access Permissions, click Edit Permission.
Ensure Remote Access is set to Allow for the user specified in the connection profile (or the group containing this user).
Under Launch and Activation Permissions, click Edit Permission.
Ensure Remote Launch and Remote Activation are set to Allow for the user.
For more information, see Securing a Remote WMI Connection on the MSDN site.
To check if Windows Firewall is active on the Spotlight client:
Possible cause… | Solution… |
---|---|
Oracle is not running. |
Verify that the Oracle instance is running and can be accessed from a host or client workstation. |
The connect string and alias of the database are incorrect or have changed. |
Check your SQL* Net configuration and verify the connect string and alias you are using are correct. |
The user ID you are using to log into Spotlight does not exist in the database. |
Run the User Wizard to establish the user ID in the database. |
The Spotlight user has the wrong permissions in the database. | Contact your DBA to add relevant permissions to the user. |
Spotlight takes too long to open the Oracle connection so it appears to be unable to connect. |
|
When installed and available, Automatic Storage Management (ASM) stores Oracle data in a separate ASM database instance. Spotlight on Oracle displays performance metrics for ASM on the home page and in the ASM drilldown.
If the database under investigation uses ASM but Spotlight cannot connect to it to retrieve the required information, you may need to edit the TNSNAMES entry for the ASM instance.
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. Términos de uso Privacidad Cookie Preference Center