Data Check : Enabled - namespace,blockmap,throttle:50%
Data Check : Disabled
Note: The first example shows that both --namespace and --blockmap scans are enabled, and the default --throttle setting (50%) is on for the DR Series system. As shown in the second example, a Data Check status of disabled indicates that both the --namespace and --blockmap scans are disabled on the DR Series system.
Disables an individual Data Check scan option type (or both scan types) when used in a DR Series system CLI command.
Syntax
system --datacheck [--disable <all | namespace | blockmap>]
Result
Data Check configuration successful: all scans currently disabled.
Note: This example shows all Data Check scan options being disabled. To disable only the namespace or the blockmap scan, use those options respectively in the DR Series system CLI command, for example, --disable --namespace, or --disable --blockmap.