Keep in mind that when you remove a DR Series system from a Global View dashboard on one system, it does not remove it from any other Global View dashboards you may have added it to on other systems.
To remove a DR Series system from Global View, complete the following:
2. |
On the Global View page, in the appliance list, click the Deletecheckbox next to the system you want to delete. Note that there is no checkbox next to the system that contains the Global View; it is not available to be removed. |
3. |
4. |
If a system administrator removes a member DR Series system from the ADS domain or if authentication to a member DR Series system fails (such as when the system is down), then the Global View dashboard displays a red icon in the Status column next to the appliance. If one or more red icons are displayed, the Reconnect Units link is enabled on the Global View page. To reconnect a DR Series system to the Global View, complete the following:
1. |
2. |
In Domain Name (FQDN), enter the fully-qualified domain name (FQDN) in which the DR Series system resides. Keep in mind that the system must be in the same login group and have identical credentials to the system on which you are working. |
3. |
In Username, enter the domain username for the DR Series system. For example, DOMAIN\administrator. This should be identical to the credentials used in all other systems in the Global View. |
4. |
In Password, enter the domain password for the DR Series system. This should be identical to the credentials used in all other systems in the Global View. |
5. |
The Reconnect DR Units Report is displayed, indicating whether the reconnection was successful or unsuccessful. If the reconnect action is successful, the Status of the connected DR Series system displays a green icon. However, if there are unresolved underlying issues such as issues with the network connection, issues with a WAN connection, or issues with the DR Series system that prevent a good connection, then the Reconnect DR Units Report indicates failure.
2. |
You can use the Support page and its Diagnostics, Software Upgrade, and License options to maintain the state of your DR Series system. To access these options, use the DR Series system navigation panel (for example, click Support→ Diagnostics to display the Diagnostics page) or use the Diagnostics, Software Upgrade, or License links on the Support page.
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. Términos de uso Privacidad Cookie Preference Center