Chatee ahora con Soporte
Chat con el soporte

Toad Data Point 6.0.5 - User Guide

Troubleshoot DB2 z/OS Issues

Review the following solutions to help troubleshoot DB2 z/OS issues in Toad.

Installation Issues

Issue Cause/Solution

Error: "Could not load file or assembly 'IBM.Data.DB2.9.1.0, Version=9.1.0.2, Culture=neutral, PublicKeyToken=7c307b91aa13d208' or one of its dependencies. The system cannot find the file specified."

You installed a commercial version of Toad for DB2 after uninstalling the freeware version.

Solution:

You must remove run time information for the freeware version of Toad from the .NET system.config file.

To remove run time information

  1. Exit Toad.

  2. Navigate to the following .NET framework directory:
    C:\WINDOWS\Microsoft.NET\
    Framework\v2.0.50727\
    CONFIG

  3. Create a backup copy of the system.config file.

  4. Open the system.config file in Notepad.

  5. Locate the <runtime> tag delete everything between the runtime tags (including <runtime> and </runtime>).

  6. Save the file.

  7. Restart Toad.

Connection Issues

Issue Cause/Solution

ERROR [08001] [IBM] SQL1336N The remote host was not found. SQLSTATE=08001  

You are attempting to connect to a database version that is not supported in Toad.

Solution:

Review the list of supported databases in the Release Notes or Installation Guide.

ERROR [58031] [IBM] SQL1031N The database directory cannot be found on the indicated file system. SQLSTATE=58031  

You do not have any catalog entries defined for the connection.

Solution:

See Configure DB2 Client Connections for more information to determine the best method for cataloging a database.

ERROR [42501] [IBM][DB2] SQL0551N "UserName" does not have the privilege to perform operation "SELECT" on object "SYSIBM.SYSSTMT". SQLSTATE=42501

You do not have SYSADM privileges for the DB2 for z/OS subsystem.

Solution:

Ensure that you are granted SELECT permissions on the DB2 catalog tables.

ERROR [] [IBM] SQL1460N The environment variable "SOCKS_NS" required for SOCKS server name resolution is not defined or not valid.

When using the Time-Sharing Option (TSO) to connect, the user ID, port number, or IP address entered may be incorrect.

Solution:

Ensure that you use the following for TSO connections:

  • DB2 user ID for the DB2 subsystem

  • Port number that DB2 listens on, for remote connections, via the DB2 DDF address space

  • IP address for the z/OS subsystem

ERROR [56038] [IBM][DB2] SQL0969N There is no message text corresponding to SQL error "-4700" in the message file on this workstation.' when connecting to compatibility mode database.

-or-

After connecting, some objects do not display properly or some functionality does not work as designed.

In general, Toad does not support a z/OS subsystem running in Compatibility mode.

Solution:

If possible, switch the subsystem's operating mode to Full Function mode.

If this is not possible, Toad now provides a message when you connect to subsystem, informing you of that the subsystem is running in compatibility mode and that some features might not be available.

Missing Functionality or Object Information

Issue Cause/Solution

Unable to browse databases in DB2 for z/OS 8 or later.

The DB2 installation job DSNTISG defines a set of DB2 procedures that the ODBC driver uses. The installation assigns these procedures (namely, those beginning with SYSIBM.SQL*) to a specific Work Load Manager (WLM) environment, which currently might not exist or be defined properly.

Solution:

Be sure that you have correctly set up and enabled the WLM environment to which the procedure definitions point.

Cannot edit data in compatibility mode.

In compatibility mode, the ODBC driver does not return enough information for the CommandBuilder to correctly generate update or insert statements.

Solution:

No solution exists. However, when you connect to a subsystem running in compatibility mode, Toad now provides a message, informing you of this condition and warning you that some features might not be available.

Other Issues

Issue Cause/Solution

Poor performance when browsing DB2 for z/OS objects in Toad. Indexes are populated slowly.

User-defined indexes on specific system catalog tables can improve performance when you are browsing DB2 for z/OS objects in Toad. The following link contains the DDL for indexes that can optimize Toad performance on your DB2 for z/OS subsystem. Keep in mind that the creation of these indexes is a recommendation only. The indexes can have different results in different environments, depending on the number of DB2 objects and the amount of data involved. To create these indexes, edit and run the DDL contained in the following file:

ToadDB2zOSIndexes.txt

Additionally, if the schema drop-down lists in the Object Migration wizard populate slowly, consider creating an index on the SCHEMA and CREATOR columns in the catalog table for each object type. Here is a list of some of the object-type tables:

SYSIBM.SYSSYNONYMS
SYSIBM.SYSSEQUENCES
SYSIBM.SYSROUTINES
SYSIBM.SYSTABLES
SYSIBM.SYSDATATYPES
SYSIBM.SYSINDEXES
SYSIBM.SYSTRIGGERS
SYSIBM.INDEXES

Encountering the S378 Abend when running IBM DB2 z/10 subsystem in Conversion mode with older versions of Toad.

This issue appears because the Toad z/OS Component tries to reference the QUEST.QC200ZPARM function.

Solution:

DROP the QUEST.QC200ZPARM function from your DB2 z/OS 10 subsystem. This will eliminate the possibility of the function being called into the WLM environment procedure and causing the S378 abend.

We do not recommend that you to just STOP the QUEST.QC200ZPARM function on the mainframe side, without actually dropping it, because that may case Toad or the batch process (QCEXEC – remote job execution) to hang. Dropping the QUEST.QC200ZPARM function is recommended.

 

Related Topics

Create DB2 Connections

Manage Connections

Connection/Navigation Manager 

Documentos relacionados

The document was helpful.

Seleccionar calificación

I easily found the information I needed.

Seleccionar calificación