El envío de formularios en el sitio de soporte no está disponible temporalmente para programar el mantenimiento. Si necesita asistencia inmediata, comuníquese con el soporte técnico. Disculpe las molestias ocasionadas.
Workload Analysis has a long loading delay and results in Error retrieving data: ClientConnectIssue: A task was canceled."
Descripción
When clicking on Workload Analysis, there is long loading delay and something follow by the error "Error retrieving data: ClientConnectIssue: A task was canceled."
Causa
The Diagnostic Server maybe out of memory. Adjust the SpotlightDiagnosticServer.ini file to increase the memory limit of the Diagnostic Server.
Resolución
WORKAROUND:
1. Backup the file {Diagnostic Server dir}\Agent\bin\SpotlightDiagnosticServer.ini into a different directory
2. Edit the file
3. Change "-Xmx4096m" to "-Xmx8192m"
4. Save the file
5. Restart the Diagnostic Server service
STATUS:
A fix is available in the latest version of Spotlight on SQL Server Enterprise which can be downloaded here.
Your Request will be reviewed by our technical reviewer team and, if approved, will be added as a Topic in our Knowledgebase.
Bienvenido al portal de soporte
Puede encontrar ayuda de soporte en línea para el *producto* Quest en un sitio de soporte afiliado. Haga clic en Continuar para ser dirigido al contenido de soporte y a la asistencia adecuados para el *producto*.