In SharePlex versions prior to 7.5, when ora_setup is run for an Oracle instance with ASM, the corresponding ASM SID is entered in the paramdb as the parameter SP_OCT_ASM_SID.
In a RAC environment when ora_setup is run for the second oracle instance SP_OCT_ASM_SID is overwritten with the second instances ASM SID.
Whenever there is a failover or failback the corresponding ASM SID is not found. This issue is seen when the ASM SID for the multiple instances of RAC is not the same.