Toad Data Point allows you to create a connection to a database that supports an ODBC 3.0 or later driver. ODBC connectivity provides basic querying capability, but may not be as full-featured as a native connection in Toad. For a list of databases tested with the ODBC provider, see the Release Notes.
This form of connectivity allows connections to databases such as Netezza, IBM iSeries, Ingres, and Vertica.
Note: Distinct values are not available in Code Completion for ODBC connections.
DSN Architecture (Bitness) Must Match Toad
To create a successful ODBC connection, the architecture (bitness) of the driver in the specified DSN must match the architecture (bitness) of Toad. For example, 64-bit Toad requires an applicable 64-bit driver and 32-bit Toad requires an applicable 32-bit driver.
To create an ODBC connection
Select an ODBC driver from the list, and click Finish.
Note: If creating an Oracle ODBC connection, select the ODBC driver provided by Oracle. The Microsoft ODBC for Oracle driver has less functionality than the driver provided by Oracle.
Specify the configuration properties required for the database in the Windows configuration dialog.
Notes:
Specify the connection properties in the Create New Connection dialog. Review the following for additional information:
General | |
Data source name |
Select the driver or data source name you added in the previous steps. |
User |
Enter the user name to use when connecting. |
Password |
Enter the password to use when connecting. Tip: After connecting, you can set a master password to further secure your connection in Tools | Options| Environment | Security. |
Database |
Select a database or schema. Click to create a temporary connection and display available databases/schemas in the drop-down list. |
Information |
|
Data Source Name |
Displays the selected driver or data source name. |
Driver |
Displays the ODBC driver associated with the data source. |
Advanced | |
Default Table Column |
Specify default options to use when creating a new table. Column type—Select the default data type to use when creating a table. Column length—For the selected column type, enter a default column length to use. |
Advanced Options |
Block Cursor Size—Specify the number of rows to return in a single fetch of data from the result set. Disable multi-threading—Multi-threading is disabled by default. Enable multi-threading only if supported by the driver. Multi-threading can improve performance, but can also result in unpredictable behavior if not supported by the driver. Default: Selected |
Category | (Optional) Select an existing category or create a new one. |
Click Connect to connect immediately while saving the connection information. Optionally, click Save to save the connection without connecting.
Tip: Connections are stored in the connections.xml file and can be found by clicking the Application Data Directory link in Help | About.
Tip | Description |
---|---|
Filter DSN by bitness |
To filter Data Source Names displayed in the New Connection dialog by the bitness of Toad, go to Tools | Options | Database | ODBC. |
Cache object metadata |
To cache object metadata for ODBC connections and retain it between sessions, go to Tools | Options | Database | ODBC and select to enable disk caching. Cached object metadata is retained until manually refreshed. |
Refresh object metadata |
To refresh object metadata for all ODBC connections, in the Object Explorer right-click an object and select Refresh All. Right-click an object and select Refresh Schema to refresh only objects in that schema. |
Feature | Description |
---|---|
Bypass schema/instance selection in SQL Editor |
For ODBC connections, in the SQL Editor you can bypass selecting a schema/instance and specify this information through the script instead. This is useful if your script executes SQL against multiple schemas. To use this method, select I will set schema/instance in the script from the schema/instance drop-down list in the SQL Editor window. Then specify the schema/instance through your script. Note: When this option is selected, some code completion features, object actions, and object information tool tips are unavailable for this SQL Editor window. |
Click here to view a video about creating connections in Toad Data Point
You can create a new connection, or connect to an existing connection from the Create New Connection window.
Click here to view a video about creating connections in Toad Data Point
Tip: You can configure Toad Data Point to accept connection information from Toad for Oracle.
You can connect to your database using a native Oracle database provider in Toad using one of the following methods:
Connection Method |
Advantages |
Disadvantages |
---|---|---|
Client connection Client tab—Uses an installed Oracle Client or Oracle Instant Client to establish a connection to the database from Toad. |
Supports LDAP See Configure Oracle LDAP Support for more information about configuring the Oracle client to use LDAP. |
Requires an Oracle client Note: Toad supports Oracle clients and Oracle Instant clients using version 9i or later. |
Direct connection Direct Connect tab—Uses TCP/IP to connect directly to the database. |
Does not require an installed Oracle Client Recommended for connecting to Oracle 8i databases |
This method only supports common data types. Some advanced Oracle object types cannot be retrieved when connecting using this method. This method does not support LDAP. (To connect using LDAP, use the Client Connection method instead.) This method cannot be used in a cross-connection query. |
Note: Quest recommends using one of the methods described in this table to connect to Oracle rather than an ODBC driver. Because ODBC connectivity is generic, it is not full-featured and may not be as robust as the fully exploited native database provider. |
Toad supports both the 32-bit and the 64-bit versions of the Oracle Client. The following table identifies which Oracle data types are supported for each client type.
Data Type | Supported Using 32-Bit Client |
Supported Using 64-Bit Client |
---|---|---|
CHAR | ||
VARCHAR2 and VARCHAR | ||
NCHAR and NVARCHAR2 | ||
LONG | ||
NUMBER | ||
DATE | ||
TIMESTAMP | ||
BLOB | ||
CLOB | ||
NCLOB | ||
BFILE | ||
RAW, LONG RAW | ||
ROWID | ||
XMLType 1, 2 | ||
SDO_GEOMETRY | ||
VARRAY | ||
Nested Table | ||
User-Defined |
Table Notes:
The Oracle Instant client installs only those files needed to connect to your database using OCI. Because this client does not write to the registry (no ORACLE_HOMES) or add to the environmental path, you must manually set environment variables so the client can be used with Toad.
To configure the Oracle Instant Client to work with Toad
Click New under System Variables and complete the following:
Variable name | Variable Value |
---|---|
PATH |
<Path where Instant Client is installed>;%PATH% For Example: C:\Program Files\OracleInstantClient;%PATH% |
TNS_ADMIN |
<Path where tnsnames.ora file is installed> |
Note: You cannot use an Oracle Direct Connection in a cross-connection query.
To create an Oracle connection
Click on the toolbar (ALT+F+N).
Select Oracle from the Group list box.
Review the following for additional information:
Login Tab | Description |
Database name |
Select the alias to use when connecting. This list displays aliases from LDAP, as well as any local tnsnames.ora file. When you initially open the connection dialog, Toad retrieves the list of LDAP names from the LDAP server. Toad caches this list and displays it upon subsequent requests, within one Toad session. To refresh the list, click . Note: If you do not select a database, Toad uses the ORACLE_SID for the selected home. If an ORACLE_SID value does not exist and you do not specify a database, you cannot connect. |
Password |
Enter the password to use when connecting. Tip: After connecting, you can set a master password to further secure your connection in Tools | Options| Environment | Security. |
Connect as |
Select whether to connect as either SYSDBA or SYSOPER if you have the appropriate permissions. Otherwise, use the default. |
Schema |
Select a schema if you frequently work in a different schema than the one associated with your user name. |
Explain plan table |
(Optional) Specify the location of an existing explain plan table to use instead of Toad automatically creating one for you when you execute a statement. This is useful if you do not have necessary permissions to create explain plan tables or want to use an existing table. |
Category |
Select or create a category if you want to color code Editor tabs for a specific connection. This can help differentiate between development and production databases. You can also set an option to color code the Object Explorer pane and object editor windows (Create, Alter, Drop, etc.). |
Save password |
Select this check box if you plan to use this connection in a scheduled Automation script. Note: This option is disabled if Toad was installed with Prohibit saving passwords selected. |
Oracle Client Tab |
Description |
Current home |
Modify the Oracle home to use, if needed. |
TNSNames Editor |
Click this button to edit your local TNSNames file. Tip: You can press CTRL+F to open the Find/Replace window to locate entries in the TNS Names Editor. Pressing F3 locates the next entry that matches your criteria. |
SQLNET Editor |
Click this button to edit SQLNET.ORA parameters. Before editing this file, you should create a backup copy. See SQLNET.ORA Profile Parameters in the Oracle documentation for more information. |
Direct Tab |
Description |
SID |
Enter the ORACLE_SID value for the database. This value is specified in the registry under each installed home. |
Advanced Tab | Description |
ODBC driver |
If an Oracle Client is installed, the default is the Oracle ODBC driver. If an Oracle Client is not installed, the default is the Microsoft Access ODBC driver. Tip: You can specify the ODBC driver to use for all connections for this database provider in Tools | Options | Database | Oracle. |
Click Connect to connect immediately while saving the connection information. Optionally, click Save to save the connection without connecting.
Note: Go to Tools | Options | Database | Oracle to specify default options to use in Oracle connections.
Tip: Connections are stored in the connections.xml file and can be found by clicking the Application Data Directory link in Help | About.
You can create a new connection, or connect to an existing connection from the Create New Connection window. See Troubleshoot SQL Server® Issues for more information about troubleshooting connection issues.
Click here to view a video about creating connections in Toad Data Point
Note: For SQL Azure connections:
Click on the toolbar (ALT+F+N).
Select Microsoft SQL Server or Microsoft SQL Azure from the Group list box.
Review the following for additional information:
Login Tab | Description |
Server name |
Enter the name of the server to use when connecting. Click to display any servers running SQL Server that are currently active on the network. Notes:
|
Authentication |
Select the type of authentication to use for this connection. You can connect to an Azure SQL database with Active Directory authentication. Client configuration is required. See https:// docs.microsoft.com/en-us/azure/sql-database/sql-database-aad-authentication-configure#configure-your-client-computers Note: You cannot create a SQL Azure connection using Windows Authentication. |
Password |
Enter the password to use when connecting. Tip: After connecting, you can set a master password to further secure your connection in Tools | Options| Environment | Security. |
Category |
Select or create a category if you want to color code Editor tabs for a specific connection. This can help differentiate between development and production databases. You can also set an option to color code the Object Explorer pane and object editor windows (Create, Alter, Drop, etc.). |
Encrypt connection |
Select this option to enable encryption for the current connection provided that the certificate has been already installed on the server. |
Advanced Tab | Description |
Network protocol |
Select one of the following:
|
Parameter Name/Value |
You can add parameters to the connection. Toad includes the Application Name parameter with value Toad Data Point by default. |
OBDC driver |
Select an ODBC driver to use for this connection when creating cross-connection queries. Tip: You can specify the ODBC driver to use for all connections for this database provider in Tools | Options | Database | SQL Server. |
Click Connect to save the connection and immediately connect to the database.
or
Click Save to save the connection without connecting to the database.
Tip: Connections are stored in the connections.xml file and can be found by clicking the Application Data Directory link in Help | About.
To import connections (including Central Management Server connections)
Specify the location where the connections currently reside.
Note: Review the following for additional information on CMS connections:
Troubleshoot SQL Server® Issues
Toad allows you to create a native Snowflake connection, which provides you with a full-featured Object Explorer, Query Builder and SQL Editor.
Note: You must have a Snowflake ODBC driver 2.24.2 (or later) installed before a native connection is created.
To install the Snowflake ODBC Driver
Download and install the ODBC Driver from the Snowflake Web site.
To create a Snowflake connection
Enter the connection information in the Create New Connection dialog. Review the following for additional information:
General tab | Description |
Host |
Enter the name of the server hosting the database to which you want to connect. |
Authenticator |
There are four types of authentication that you can use to connect to Snowflake in Toad. The required Login fields will change according to the type of authentication you select. All the authenticators are located in a dropdown list:
|
User | Enter the username for your Snowflake account |
Password | Enter the password for your Snowflake account |
Token | Enter your authentication token (Only visible when connecting via OAuth) |
Port |
The default port number for Snowflake is 443 |
Optional |
A connection can be made without providing this information |
Role | Enter the User role that you would like to connect to |
Database | Enter the name of the database you would like to connect to |
Warehouse | Enter the name of the Warehouse you would like to connect to |
Click Connect to save the connection and immediately connect to the database
OR
Click Save to save the connection without connecting to the database.
When using SSO or MFA, there is a way to maintain continuous and secure connectivity without needing to enter login credentials for each connection attempt to Snowflake (as well as to prevent additional browser loading whenever a new module is started in Toad Data Point). To achieve this, check whether the correct parameters have been set in your account by executing the query below in your Snowflake cloud interface:
SHOW PARAMETERS IN ACCOUNT;
The output that will secure login credentials caching will have these values:
For SSO
allow_id_token = true;
For MFA
allow_client_mfa_caching = true;
If these values are set to false, then the following queries need to be executed:
For SSO:
ALTER ACCOUNT
SET allow_id_token = true;
For MFA:
ALTER ACCOUNT
SET allow_client_mfa_caching = true;
Note:
If a Role or Warehouse isn’t chosen, the default settings from the Snowflake User account will be applied (it is considered best practice that a user sets a default Role and a default Warehouse in their Snowflake user account).
Tip:
It is strongly advised to use only the Snowflake user account authentication when creating Automation scripts to avoid unnecessary workflow interruptions.
Tip: Connections are stored in the connections.xml file and can be found by clicking the Application Data Directory link in Help | About.
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. Nutzungsbedingungen Datenschutz Cookie Preference Center