Enables or disables data verification on read.
Adds a data storage expansion shelf (enclosure) to a DR Series system. Each expansion shelf that is added to a DR Series system requires an individual service tag and a license. For information about the maximum allowable expansion shelves and their capacities, see the DR Series System Interoperability Guide and the DR Series System Administrator Guide at support.quest.com/DR-Series.
For more information about the required licenses, see system --show [--license] [--verbose] and system --license [--validate] [--add].
|
NOTE: To verify the current types of storage on a DR Series system, use the DR Series system CLI command: system --show --storage. For more information, see system --show [--storage]. |
Turns on an LED that is used in locating a specific physical disk or data storage expansion shelf (using the system --storage command) in the DR Series system. Select from the following DR Series system CLI command options:
• |
--blink: turns on LED on the physical disk or expansion shelf to identify it. |
• |
--type <internal | external>: identifies storage as an internal physical disk or external expansion shelf. |
• |
--service_tag <service tag>: identifies physical disk or expansion shelf by its unique service tag. |
• |
--disk <slot num>: identifies the disk slot number (if no disk slot is defined, it globally affects all disks). |
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. Nutzungsbedingungen Datenschutz Cookie Preference Center