• |
Foglight ® for DB2 LUW utilizes a lightweight agent that provides real-time monitoring of all layers of an enterprise application (systems, networks, Internet, and databases) and captures pertinent infrastructure application usage, service, and availability level data used to continually assess the state of an DB2® LUW installation. Using this collected data, Foglight Management Server provides a multi-dimensional view of resource utilization for capacity planning, problem determination, and trend analysis, both real-time and historically.
On-demand dashboards does not work on Federation Master. Workaround: View the data on the child FMS or enable RMI on the Federation Master by changing the value of “DBWC_Use_Callback_Instead_RMI” registry variable to “false“ followed by disabling and enabling the Oracle DB UI cartridge. | |||||||
Setting User Defined Collection Credentials for DB2 will fail, when the DB2 agent name contains the character @. | |||||||
Workaround: Click “Info” icon on the right corner of the page and see the warning message. | |||||||
The Management Server 5.7.1 stops responding when clicking charts on the Tablespaces dashboard. Workaround: Upgrade the Management Server to 5.7.5 or later. | |||||||
If your DB2 version is 10.1, granting user permission may fail due to inconsistent parameter(). | |||||||
If you select either of DB_DB2, DB_DB2_UI, DB_Global_View_UI cartridges then click Reset on the Cartridge Inventory dashboard, the upgrade wizard will prompt again.
| |||||||
DB2 SQL Performance doesn't support DB2 version lower than v9.7.0.10 (excluding 9.7.0.10). | |||||||
Workaround: See the warning message on the right corner of the page. | |||||||
In Upgrade Wizard, when upgrade finishes (click the Finish button), there will be low chance that the page will navigate back to the beginning of the Wizard.
| |||||||
Workaround: On the Foglight Agent Manager machine, the “description” limit is configured to “1024”. This value should be defined as “unlimited” or to a larger number, for example “65535”. | |||||||
When you are finished, both online help versions are displayed in the action panel. | |||||||
Workaround: Upgrade to Foglight Management Server 5.6.4 or later. | |||||||
The DB2 installer does not support foreign languages on Windows machine. The DB2 agent should be created manually through Foglight Administration > Agent Status. The fields that needs to be modified are: Once the agent was activated, the following errors may be occurred: | |||||||
For DB2 version 9.7 and above, the following metrics are not available due to DB2 limitations: AGENT_USR_CPU_TIME_MS, AGENT_SYS_CPU_TIME_MS, LAST_RESET. | |||||||
The Databases dashboard does not appear after user upgrades the Foglight for DB2 LUW to 5.7.5.37 using SPM installer. | |||||||
The “Error executing script” error shows in the server log, if user clicks any tab or component on the Global View. | |||||||
An error log showed in FMS log for loading heatmap component in FMS version before 5.9.3. | |||||||
Anti-virus software may negatively impact the CPU and system performance of machines running Foglight. To reduce resource consumption, it is highly recommended to exclude the relevant directory, processes, and executables from being scanned by the anti-virus software. For detailed information, refer to the “Configuring anti-virus exclusion settings” in Installing Foglight on Windows with an Embedded PostgreSQL Database. | |||||||
Workaround: When upgrading Foglight to 6.0.0, first upgrade the FMS to 6.0.0, then directly upgrade the cartridges. |
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. Nutzungsbedingungen Datenschutz Cookie Preference Center