立即与支持人员聊天
与支持团队交流

Foglight for Storage Management Shared 4.6.5 - User and Reference Guide

Getting Started Monitoring Storage Performance Investigating Storage Devices Investigating Storage Components Investigating VPLEX Storage Troubleshooting Storage Performance Managing Data Collection, Rules, and Alarms Understanding Metrics Online-Only Topics

Fabrics and FC Switches — Performance Metrics

For fabrics and switches, performance is assessed in terms of send and receive values for the FC switch ports and is expressed as the average number of bytes per second or frames per second. Port errors are also an important indicator of port performance, because a higher number of errors correlates with lower send and receive values.

A range of normal values, as determined by IntelliProfile by looking at historical data for the same time range. A baseline range displays after seven days of data collection.

n/a

Bytes per second sent and received though a port.

bytesTotal

Average number of bytes per second received through a port. The data rate, compared against the Baseline of typical activity, indicates whether the current traffic is typical or out of the norm.

bytesRcvd

Also Data Xmit Rate

Average number of bytes per second transmitted through a port. The data rate, compared against the Baseline of typical activity, indicates whether the current traffic is typical or out of the norm.

bytesXmit

Average number of frames per second received and transmitted through a port.

framesTotal

Average number of frames per second received through a port.

framesRcvd

Also Frame Xmit Rate

Average number of frames per second transmitted through a port.

framesXmit

Average number of link errors per second on a port. Link errors are caused by or affect the link status of the connection. Link errors include:

If an error rate value is very small, it may be displayed as 0.0. If a fabric or switch has an actual error rate of 0, it is not displayed.

errorsLink

Current speed of a port in Mb/second.

currentSpeedMb

Average number of non-link errors per frame on a port. Non-link errors include:

If an error rate value is very small, it may be displayed as 0.0. If a fabric or switch has an actual error rate of 0, it is not displayed.

nonLinkErrors

= Data Receive Rate / Link Speed, expressed as a percentage. Utilization values help you identify ports that may be overloaded.

bytesRcvdUtilization

= Data Send Rate / Link Speed, expressed as a percentage. Utilization values help you identify ports that may be overloaded.

bytesXmitUtilization

Storage Arrays and Filers — Disk I/O Performance Metrics

Rate and latency metrics describe the performance of ports, controllers, pools, LUNs, disks, and NASVolumes. The selection of performance metrics displayed in any given dashboard depends on the selected device type and the metrics available from the device vendor.

Also displayed as Pct Busy or Busiest

Average percentage of time a component is busy doing I/O during the collection period.

busy

Average number of outstanding I/O operations at the start of each new I/O request in a pool, LUN, or disk.

avgQueueDepth

Percentage of read operations that can be satisfied from the cache.

cacheHits

Percentage of read operations that can be satisfied from this cache.

cacheHitRate_L1

Percentage of read operations that can be satisfied from this cache.

cacheHitRate_L2

Bytes per second read and written.

bytesTotal

Bytes per second read.

bytesRead

Bytes per second written.

bytesWrite

Average latency for read/write operations to the disks in a pool, calculated in milliseconds per operation. At the pool level, Avg Disk Latency reflects the average latency for I/O to the physical disks.

latencyTotalDisk

(R/W Latency)

Average latency for read/write operations, calculated in milliseconds per operation. At the pool level, Latency reflects I/O to the pool only. If the block of data to be read is already in a cache, then the latency for that operation is very low, because no disk access needs to be performed.

NOTE: Latency is not the sum of read latency and write latency. The number of read operations and write operations is different.

latencyTotal

Average latency for other operations

latencyOther

Average latency for read operations.

latencyRead

Average latency for write operations.

latencyWrite

Average read and write operations per second.

opsTotal

Read operations per second.

opsRead

Write operations per second.

opsWrite

Other operations per second.

opsOther

Clustered Storage Arrays — Network Performance Metrics

These metrics describe the performance of an EqualLogic array’s network and an Isilon array’s internal and external networks.

Current operational speed of the port link.

currentSpeedMb

Rated maximum speed of the port

maxSpeedMb

Number of incorrectly received data packets divided by the total number of received packets, expressed as a percentage.

packetErrorPercent

Bytes per second received through a port or group of ports.

bytesWrite

Bytes per second sent through a port or group of ports.

bytesRead

= Rcv Data Rate / Link Speed

bytesWriteUtilization

= Send Data Rate / Link Speed

bytesReadUtilization

Also NW Rcv Util (% of max)

= Rcv Data Rate / Max Port Speed

bytesWriteUtilizationMax

Also NW Send Util (% of max)

= Send Data Rate / Max Port Speed

bytesReadUtilizationMax

Capacity Metrics

The selection of capacity metrics displayed in any given dashboard depends on the selected device type and the metrics available from the device vendor. The following tables define each metric and shows the topology name for the metric. You need the topology name when referencing the metric in user-defined rules and dashboards.

Capacity metrics are organized into the following categories: