sp_ctrl> status
Capture - stopped due to error
Indicates that capture process is stopped due to error.
There are a number of reasons that the capture process can be stopped due to error. The event log will give more specific information regarding the error.
In sp_ctrl execute the command below:
sp_ctrl>show log reverse
This provides the error message :
Example:
Notice: FioSetEnsure: set redolog_ensure to 1[sp_ocap/13289] Error: Alloc: User initialized, not in table
0x0a0af261+PA+o.lp01d+sp_ocap+o.lp01d [sp_ocap(shs)/13289]
Notice: shs_alloc_stat (0): Failed with error shs_ALLALLOCED: no more memory to allocate [sp_ocap(shs)/13289]
Error: 10744 - sp_ocap shs init failed [sp_ocap/13289]
Process exited sp_ocap (for o.lp01d) [pid = 13289] -
exit(1)"
Search our knowledge base for the error you see in this output for resolution.
In this case search for Error: 10744 - sp_ocap shs init failed.
ADDITIONAL INFORMATION:
Run the "show log reverse" command to read the last messages in the event log to determine the exact error, then search the knowledge base for that error.