NetVault Smart Client Service stopped and wouldn't restart after nine seconds.
We could see the following errors from the Smart Client Process Manager Trace:
2 PMGRNT ??? 2704 143 0 103859855844 Thread with handle 0000027C has completed
3 PMGRNT ??? 2704 145 0 103859855844 Dead process 'Network Manager' at 0147B7B0
3 PMGR ??? 2704 64 0 103859855844 PmgrProcessChildDeath(0147B7B0)
5 PATH ??? 2704 10 0 103859855844 PathHomeBuild returning "/dump"
5 PATH ??? 2704 5 1 103859855844 Failed to create directory '/dump'
5 DIRSCAN ??? 2704 9 0 103859855844 Scan 'C:\Program Files (x86)\BakBone Software\NetVault\tmp\*.*'
5 DIRSCAN ??? 2704 9 0 103859855844 Scan 'C:\Program Files (x86)\BakBone Software\NetVault\tmp\*.*'
0 PMGR ??? 2704 67 0 103859855844 Network manager has died, exiting...
We could also see the following errors from the Smart Client Network Manager Trace:
2 NETLOOP ??? 2296 3 0 103859762224 NmgrNewMachine(0x0996F854, 0x09A9C830, 724)
2 NETLOOP ??? 2296 439 0 103859762224 New machine 'uklon_svnmaster'
3 NETLOOP ??? 2296 4 0 103859762224 New machine initial state DISCONNECTED
0 NETLOOP ??? 2296 437 0 103859762224 Failed to get networks key for machine 'uklon_svnmaster' - aborting
3 NETLOOP ??? 2296 617 0 103859762224 FALSE = NmgrLoadMachineInfoUDP()
0 NETLOOP ??? 2296 625 0 103859762224 Failed to process 'C:/Program Files (x86)/BakBone Software/NetVault/etc/machines.dat'
3 NETLOOP ??? 2296 121 0 103859777845 FALSE = NmgrLoadMachineInfo()
3 NETLOOP ??? 2296 127 0 103859777845 FALSE = NmgrInitialize()
2 NETLOOP ??? 2296 205 0 103859777845 Failed to initialize network manager system
0 PMGRNT ??? 2296 114 0 103859777845 Failed to start network loop
5 PROCESS ??? 2296 13 0 103859777845 ProcCleanup(1)
5 PATH ??? 2296 10 0 103859777845 PathHomeBuild returning "C:/Program Files (x86)/BakBone Software/NetVault/config/monitor.cfg"
0 FILESYS ??? 2296 31 2 103859777845 Failed to open C:/Program Files (x86)/BakBone Software/NetVault/config/monitor.cfg error The system cannot find the file specified.
5 FILE ??? 2296 16 0 103859777845 Failed to open file stream 'C:/Program Files (x86)/BakBone Software/NetVault/config/monitor.cfg'
5 PROCESS ??? 2296 11 0 103859855844 ProcRelease(1)
5 PROCESS ??? 2296 5 0 103859855844 TRUE = ProcSendStatus(4)
5 CONTEXT ??? 2296 2 0 103859855844 bError = FALSE bInitializeThreadContext = FALSE
5 NET ??? 2296 148 0 103859855844 Socket 656 has read select not set
5 NET ??? 2296 124 0 103859855844 Socket 672 has read select set
0 NET ??? 2296 84 0 103859855844 Connection down
Unfortunately there was nothing in the dump files that could help us further.
This was pointing to a networking/communication issue and eventually the connection was lost.
The Smart Client (SC) is trying to communicate to another Client ('uklon_svnmaster') and then went down.
The Smart Client service shouldn't normally stop if a Client cannot be contacted.
So we added the 'uklon_svnmaster' Client to the NetVault Server Client Management (as may have been removed before) and then tried to start the Smart Client Services again.
Unfortunately this didn’t resolve the issue.
We then moved the machines.dat file that is under the …\NetVault Backup\etc folder to a safe place and then started the NetVault Services on the Smart Client again. This will then create a new machines.dat file. The machines.dat file contains all the machines details that it can communicate with.
The NetVault Services then ran and stayed running and the NetVault Server Device Management window was showing all the devices online again.
So the issue was a corrupt machines.dat file on the SC.
© 2025 Quest Software Inc. ALL RIGHTS RESERVED. Terms of Use Privacy Cookie Preference Center