Choice of conversion methods for complex recurring meeting series: A new boolean program parameter offers admins a choice of how NME will process certain complex recurring meeting series where the series parent is difficult to identify. For example:
[Notes]
UseLegacyMeetingParentHeuristic=0
... tells NME to apply the alternate conversion method that is better suited to such series. By default (1) NME uses the previous method, which is better suited to environments migrating few or no such series.
WORKAROUND
Within Notes Migration Manager:
1. Select File | Global Default Settings.
The program then opens the Global Default Settings into Windows Notepad. Within Notepad, the settings
look like the contents of an INI file, but they are actually saved as a part of the SQL Server database
rather than as an independent INI file.
2. Find the pertinent [Section] for the parameter whose value you want to specify or edit.
3. Add the parameter or edit its value, as appropriate.
[Notes]
UseLegacyMeetingParentHeuristic=0
4. Close Notepad.
Notes Migration Manager will then copy the new parameter value(s) back into the SQL Server database.