When new LiteSpeed maintenance plan is created, it fails to run with the following error message appearing in the Job History:
Executed as user:user_name. Microsoft (R) SQL Server Execute Package Utility Version 9.00.3042.00 for 32-bit Copyright (C) Microsoft Corp 1984-2005. All rights reserved. Started: 2:34:32 PM Warning: 2008-10-15 14:34:34.21 Code: 0x80012017 Source:plan_nameDescription: The package path referenced an object that cannot be found: \Package\Subplan 1.Disable. This occurs when an attempt is made to resolve a package path to an object that cannot be found. End Warning DTExec: Could not set \Package\Subplan 1.Disable value to false. Started: 2:34:32 PM Finished: 2:34:34 PM Elapsed: 1.234 seconds. The package execution failed. The step failed.
WORKAROUND:
The REGSVR32DTS.DLL should be reregistered.
1. Select Start | Run | type REGSVR32DTS.DLL | Click OK
2. An on screen message will display indicating that the DllRegisterServer in DTS.DLL has succeeded.