지금 지원 담당자와 채팅
지원 담당자와 채팅

DR Series Software 4.0.3 - Administration Guide

Introducing the DR Series system documentation Introducing the DR Series system Setting up the DR Series system Configuring the DR Series system settings Managing containers Managing replications Monitoring the DR Series system Using GlobalView Configuring and using Rapid NFS and Rapid CIFS Configuring and using Rapid Data Access with NetVault Backup and with vRanger Configuring and using RDA with OST
Understanding RDA with OST Guidelines Terminology Supported RDA with OST software and components Best Practices: RDA with OST and the DR Series System Setting client-side optimization Configuring an LSU Installing the RDA with OST plug-in Configuring DR Series system information using NetBackup Backing up data from a DR Series system with NetBackup Using Backup Exec with a DR Series system (Windows) Understanding the OST CLI commands Understanding RDA with OST Plug-In Diagnostic Logs Collecting diagnostics by using a Linux utility Guidelines for gathering media server information
Configuring and using VTL Configuring and Using Encryption at Rest Support, maintenance, and troubleshooting Supported Ports in a DR Series system About us

DR Series System NVRAM

NVRAM is a field replaceable unit (FRU) in the DR Series system (Note: NVRAM is not part of the DR4300e Core system). The super capacitor that powers the NVRAM double-data rate (DDR) memory must be able to move its contents to the solid-state drive (SSD) during a power loss.

This data transfer requires maintaining the power to run the system for 3 minutes of operation (normally, it only takes approximately one minute). If a problem occurs during the data backup to the SSD, the subsequent system reboot detects this. NVRAM can experience backup failure when the following occurs:

If any of these conditions occur, the NVRAM requires either a failure recovery or a replacement.

NVRAM Backup Failure Recovery

After you have physically replaced the NVRAM card in a PCIe x4 (or x8) slot in the DR Series system chassis, you can recover from an NVRAM backup failure by completing the following tasks:

CAUTION: You must wait a minimum of 20 minutes after powering on the DR Series system before using the DR Series system CLI maintenance --hardware --reinit_nvram command. This 20–minute post power-on waiting period allows the NVRAM card, the super capacitor calibration, and all solid state drive (SSD) processes to fully complete, which are necessary for the proper operation of the DR Series system.

During Maintenance mode, the DR Series system determines, detects, and repairs the data loss. During the system reboot process, it ensures that no valuable data remains on the NVRAM.

1.
Enter the following DR Series system CLI command: maintenance --hardware --reinit_nvram.

NVRAM Field Replacement

Whenever the DR Series system NVRAM is replaced in the field, you must observe this best practice procedure:

CAUTION: You must wait a minimum of 20 minutes after powering on the DR Series system before using the DR Series system CLI command: maintenance --hardware --reinit_nvram. This post power-on waiting period allows the NVRAM card, the super capacitor calibration, and the SSD processes to fully complete, which are necessary for the proper operation of the DR Series system.
2.
Enter the following DR Series system CLI command: maintenance --hardware --reinit_nvram.

Troubleshooting error conditions

To troubleshoot error conditions that disrupt your normal DR Series system operations, complete the following:

관련 문서

The document was helpful.

평가 결과 선택

I easily found the information I needed.

평가 결과 선택