Spotlight on Oracle 10.7 - Getting Started Guide

Welcome to Spotlight Install Spotlight Start Spotlight Spotlight on Oracle Spotlight on Oracle Data Guard Spotlight on Oracle RAC Spotlight on Unix Spotlight on Windows Spotlight on MySQL Troubleshooting: Connection Problems

Sequential Read Time Alarm (calibrated)

The Sequential Read Time alarm is activated when the average time that Oracle takes to read a single block of data — typically an index-based lookup — is significantly higher than the average time recorded during calibration.

Single block reads that take too long to complete may indicate a disk bottleneck or other I/O-related issue.

 