Date: 05/07
Affected NV Version: All up to 7.4.5
OS Version: All
Plugin version: N/A
Application version: N/A
Description: Occasionally tapes are marked read only. When you uncheck the 'read only' box in the properties of the tape, the tape is scanned, but fails, and is marked unusable. Blanking the tape makes the tape work normally again. This is because the drive is not configured to stop writing to the tape soon enough, and winds up reaching the end of the tape before it can write a terminator to the end of the segment. Amount of media reserved at end of tape (MB) sometimes has a default setting of 25MB, which will cause the problem.
Symptoms:
SCSI :2276 25 0 220632 CMD WRITE [ 0a 01 00 00 01 00 ]
SCSI :2276 17 0 220632 CMD SENSE KEY 'VOLUME OVERFLOW EOM ' [d] - ASC 00 ASCQ 02
SCSI :2276 18 0 220632 CMD SENSE INFO 'END-OF-PARTITION/MEDIUM DETECTED'
Error 2007/05/26 15:06:32 596 Media NVSERVER NVSERVER 2-0.2.0 (SONY SDX-700C): had media error
Error 2007/05/26 15:06:32 596 Media NVSERVER Error transferring data to Mid '5551212', marked read only
Error 2007/05/29 11:44:47 0 Media NVSERVER Error terminating media '5551212' <Full> in 'NVSERVER: 2-0.0.0 (QUALSTAR TLS-4420): DRIVE 2:NVSERVER' at end of scanning