Date - May 2008
Affected Product & Version - Netvault Backup v8.0 U2
Affected Module & Version - MySQL APM v3.0.1.8
OS Version - MS Windows x8632
Application Information - Mysql v5.0.51a-community-nt MySQL Community Edition
Description:
MySQL - Bug 11824 periodically causes the MySQL APM backup jobs to fail when a *.MYD file remains in the Windows TEMP folder.
Symptoms:
After Backup of some tablespaces, NV shows "backup completed" but in the trace file, there's error messages:
"Error: CloseHandle(hPipe) failed with error 109: The pipe has been ended."
Although the backup job reports success, the Table data backup fails.
If users restore data from such erroneous Backup saveset, the restore fails.
This is a known issue reported against MYSQL, Please refer to MySQL Knowledge Base for additional information at: http://bugs.mysql.com/bug.php?id=11824
© 2021 Quest Software Inc. ALL RIGHTS RESERVED. Feedback Terms of Use Privacy