When two Toad Automation tasks happen to run simultaneously, one of the following errors may result:
1. System.IO.IOException
The process cannot access the file 'C:\Users\<user>\AppData\Roaming\Quest Software\Toad Data Point <version>\Connections.xml' because it is being used by another process.
2. IOException
The process cannot access the file 'C:\ProgramData\Quest Software\Toad Data Point <version>\license.key' because it is being used by another process.
3. System.IO.IOException
The process cannot access the file 'C:\Users\<user>\AppData\Roaming\Quest Software\Toad Data Point <version>\Layouts\Editor.xml' because it is being used by another process.
4. ObjectDisposedException
Cannot access a disposed object.
Object name: 'MainForm'.
5. System.NullReferenceException
Object reference not set to an instance of an object.
Both tasks try to access the same files in the application data folder for Toad.
WORKAROUND:
None
STATUS:
Waiting for fix in a future release of Toad for Data Point.