The Root Cause Analyzer report causes the FMS stop responding and requires it to be restarted.
When there are a large number of database instances in the group (over 200) the issue occurs.
When there are only two database instances in the group the issue does not occur.
RESOLUTION 1
Reduce the number of instances in the database group.
RESOLUTION 2