IP address in workstation with higher metric will not validate due to
binding order. When a workstation has several IP addresses (virtual
network, VPN address or different network devices are connected like
WiFi and Ethernet) the network binding will show only the one address with the smallest metric value. Even though the IP address for one device matches the IP range, the main address is different and it is not validated by the logic.
A dynamic variable can be created in Global Options to check if any of the IP addresses assigned to any device matches the logic to be validated. To create this variable:
Now there will be a dynamic variable named $IPRange (1 if any IP address is in selected range, 0 otherwise).
To use this variable, the validation logic rule for custom variable can be used:
This value will confirm the logic for the element validation.