WORKAROUND
Steps to apply (helpful screenshots also included)
1. Logon to FMS console with user that has "Cartridge Developer" role
2. Navigate to Configuration > Defintions: and select "Databases"
3. Find the view "Databases Explorer" and edit
4. Move to "Context" tab and create an input in the "Additional" section
a. Name it "groupInstances-explorer"
![](https://prod-support-images-cfm.s3.amazonaws.com/KB_kA0RP0000001qKj0AI_Step4a-Database Explorer.jpg)
b. Select binding > List
c. Check all three "Merge Lists", "Remove Nulls", "Remove Duplicates"
![](https://prod-support-images-cfm.s3.amazonaws.com/KB_kA0RP0000001qKj0AI_Step4b_c-groupInstances.jpg)
d. Add 5 items to the list
1) gvNodes
2) ASMInstances: Path -> clustersGlobalView
3) CRS: Path -> clustersGlobalView
4) ExadataInstances: Path -> clustersGlobalView
5) DataGuardInstances: Path -> clustersGlobalView
e. Move the "groupInstancesExplorer" node above "values"
5. Edit the input "values" and set "groupInstancesExplorer" as the first parameter instead of gvNodes
![](https://prod-support-images-cfm.s3.amazonaws.com/KB_kA0RP0000001qKj0AI_Step5-values.jpg)
6. Save the View.
STATUS
This issue has been logged as defect FOG-9046 and will be fixed in the updated Global View cartridges.