SharePlex Manager 3.1 - Release Notes

Known Issues

The following is a list of issues known to exist at the time of this release.

Known Issue Defect ID
If the same SharePlex instance belongs to more than one stream, it will be listed multiple times in the Instance field drop-down list in the Parameter console (once for each stream it belongs to). Also, if the same instance acts as both a Source and Target, it will be listed twice: one entry will be the source entry that when selected will show the source modules; the other entry will be the target entry that when selected will show the target parameter modules. This means that to set the same value for Import, Export, or Post process parameters for a SharePlex instance in all the streams it is a part of, you must set that parameter in each stream separately using the “ALL” setting in the Queue Name field.

57320

Supplemental logging must be ON or else activating configuration will fail with wrongly worded "A bad configuration file." 87972

System Requirements

SharePlex Manager must be installed on a Foglight 6.1 Management Server (FMS) and requires that SharePlex be installed on all the hosts that you want to monitor.

Note: To learn more about the system requirements for Foglight, refer to the Foglight System Requirements and Platform Support Guide of respective Foglight version.

Hardware

Requirement Details

CPU

4-way 2.4 GHz CPUs - one of the following:

  • 1 quad core
  • 2 dual core
  • 4 single core
RAM

4 GB in total:

  • 2.4 GB for Management Server (1.6 GB for Heap, 0.8 GB for JavaTM Virtual Machine)
  • 0.8 GB for database repository
  • 0.8 GB for operating system

Storage

If using built-in embedded database repository:

  • 120 GB, 10000 RPM hard disk or better

If using external database repository:

  • For Management Server: 40 GB, 7200 RPM hard disk or better
  • For Database Repository: 80 GB, 10000 RPM hard disk or better

Operating System

Operating System Version OS Architecture 32-bit 64-bit
CentOS Linux 7.x and 8.x* x86-64   1
Microsoft Windows Server 2019 and 2022 x86-64
Microsoft Windows Server 2016 x86-64
Oracle Linux 7.x and 8.x* x86-64
Red Hat Enterprise Linux 7.x and 8.x* x86-64

Table Notes: On 64-bit RPM-based Linux platforms, the 32-bit version of libgcc*.rpm must be installed for the installer and Management Server to run.

*Limitation: In the current release, SharePlex Manager does not support RHEL 8.9, CentOS Linux 8.9, and Oracle Linux 8.9.

SharePlex

SharePlex Manager can be used with the following versions of SharePlex:

  • 10.x
  • 11.1
  • 11.2
  • 11.3

High Availability

High availability for SharePlex Manager is supported in SharePlex 10.0 and later as follows:

  • Quest Foglight for Oracle High Availability 6.1 must be installed on each of two high-availability servers and configured in High Availability mode. Monitoring of SharePlex occurs only on the active node. For more information, see the Foglight documentation at https://support.quest.com/foglight.
  • The Foglight repository must be installed in an external Oracle database that is accessible by both servers.
  • SharePlex Manager must be installed on both servers.

Product Licensing

Product Licensing

Quest SharePlex Manager is available with the purchase of Quest SharePlex. The current license model for SharePlex is to license for a specific host which, depending on edition, is licensed by core(s) or socket(s) and specific message repository (i.e. database, JMS/text files) etc. Specifics of license terms should be obtained from your account manager. To activate a SharePlex license, see the SharePlex Release Notes.

Getting Started with SharePlex Manager

Contents of the Release Package

The SharePlex Manager release package contains the following products:

  1. SharePlex Manager  3.1
  2. Product Documentation, including:
    • Product Documentation, including SharePlex Manager User Guide and SharePlex Manager Installation Guide.

Installation Instructions

Refer to the SharePlex Manager Installation Guide for installation instructions.

Upgrade and Compatibility

For information on upgrading SharePlex Manager from any previous version to 3.1, please see upgrade folder for cartridge only installation and upgrade instructions.

NOTE: Upgrade/Installs may not take effect until the Foglight/Forge service and SharePlex Manager service is restarted. Also, cartridge only upgrade installation should only be used when upgrading from 3.0 or earlier versions. See the SharePlex Manager Installation Guide included with this release.

Documentos relacionados

The document was helpful.

Seleccionar calificación

I easily found the information I needed.

Seleccionar calificación