In this scenario, mail may stop flowing through the CMN Mail Connector. The following error will be seen in the CMN Mail Connector log file:
InvalidOperationException: Cannot load Counter Name data because an invalid index '' was read from the registry
Stack Trace: at System.Diagnostics.PerformanceCounterLib.GetStringTable(Boolean isHelp)
at System.Diagnostics.PerformanceCounterLib.get_NameTable()
at System.Diagnostics.PerformanceCounterLib.get_CategoryTable()
at System.Diagnostics.PerformanceCounterLib.CounterExists(String category, String counter, Boolean& categoryExists)
at System.Diagnostics.PerformanceCounterLib.CounterExists(String machine, String category, String counter)
at System.Diagnostics.PerformanceCounterCategory.CounterExists(String counterName, String categoryName, String machineName)
at System.Diagnostics.PerformanceCounterCategory.CounterExists(String counterName, String categoryName)
at CMX.API.Core.NonNullPerformanceCounter..ctor(String name, String help, PerformanceCounterType type, String categoryName)
at CMN.API.MailConnector.MessageProcessing.ExchangeToDominoMessage.PerformanceCounters..ctor()
Run the following command(s) from a Administrator Command Prompt to recreate the index:
cd C:\windows\system32
C:\windows\system32> lodctr /R
You may get the following error:
Error: Unable to rebuild performance counter setting from system backup store, error code is 2
If so, then run
cd C:\windows\SysWOW64
C:\windows\SysWOW64> lodctr /R
Restart the Quest CMN Mail Connector Service