Issue
In some environments when the EV Collector Modules attempts to collect metadata from large journal archives, a SQL timeout may be experienced. This article explains possible ways to work around this.
Solution
It is strongly recommended to review the SQL Server specification versus the recommended levels in the Archive Shuttle documentation.
The following error below may be seen in the EV Collector Module log file. The error is about timeout from EV SQL, as EV Collector is collecting journal item metadata from EV SQL server.
2015-02-18 21:36:43Z|6216| 13|ERROR| CollectItemsForSingleArchive|Error while collecting items for Journal Archive 01. Void OnError(System.Data.SqlClient.SqlException, Boolean)
Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding.
at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection)
at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection)
at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj)
at System.Data.SqlClient.SqlDataReader.ConsumeMetaData()
at System.Data.SqlClient.SqlDataReader.get_MetaData()
at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async)
at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, DbAsyncResult result)
at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method)
at System.Data.SqlClient.SqlCommand.ExecuteReader(CommandBehavior behavior, String method)
at System.Data.SqlClient.SqlCommand.ExecuteReader()
at ArchiveShuttle.Module.EVCollectorModule.EvItemsGatherer.QueryArchivedItems(EVArchive evArchive, DateTime colFrom, String sqlstring, SqlConnectionStringBuilder connectionString, Int64 pageNumber, Int64 rowsPerPage)
at ArchiveShuttle.Module.EVCollectorModule.EvItemsGatherer.GatherArchivedItems(EVArchive archive, DateTime colFrom)
at ArchiveShuttle.Module.EVCollectorModule.EvItemsGatherer.CollectItemsForSingleArchive(EVArchive archive)
The EV Collect module .exe.config file has two settings which can be adjusted in order to try to work around this issue.
Change the SQL Command Timeout from 600 to 1200 or 1800. The above entries in the config file would now look like this:
Change the RowsPerPage option to return large batches of data during each cycle. The default value is shown below (near the bottom of the .exe.config file)
100000
Change the value to 250000:
250000
Once these changes have been made, restart the EV Collector Service.