立即与支持人员聊天
与支持团队交流

Foglight for VMware 5.7.7 - User and Reference Guide

Using VMware Monitoring in Foglight for Storage Management Reference Appendix: Alarm Messages Appendix: Metrics

VMW Datastore Estimated Fill Time

This rule determines when the datastore is likely to reach its capacity, based on its present growth rate.

VMWDatastore

Table 54. Rule Definition

At the present growth rate, the datastore will not reach its capacity within 90 days.

Normal

None

At the present growth rate, the datastore will reach its capacity in 90 days or less.

Warning

None

At the present growth rate, the datastore will reach its capacity in 30 days or less.

Critical

Send email to VMware administrator

At the present growth rate, the datastore will reach its capacity in 7 days or less.

Fatal

Send email to VMware administrator

VMW Datastore Inactive

This rule detects when a datastore becomes inactive in vSphere.

VMWDatastore

The datastore is currently active.

Normal

None

The datastore is currently inactive.

Warning

None

Resource Pool Rules

This section describes the resource pool rule:

VMW Resource Pool Disk IO

This rule monitors for spikes and dramatic drops in disk IO for a resource pool.

VMWResourcePool

Table 56. Rule Definition

The disk usage is no more than 2.2 standard deviations (NumSTDevs) from the mean disk usage.

Normal

None

The disk usage is more than 2.2 but no more than 2.8 standard deviations from the mean disk usage.

Warning

None

The disk usage is more than 2.8 standard deviations from the mean disk usage.

Critical

None

The views listed in Rules , in addition to the Resource Pools Relationship Tree view .