The Quest Reporter Node Installer service terminated with the following error: The requested operation completed successfully. The system will be restarted so the changes can take effect (4315058)
The Quest Reporter Node Installer service terminated with the following error: The requested operation completed successfully. The system will be restarted so the changes can take effect
说明
The Windows Installer initiated a system restart to complete the configuration of 'Quest Enterprise Reporter Node'.
原因
This behavior can occur during the upgrade process, if the Clusters/Nodes are not disabled first. Dll's in memory may be locked, so the installer cannot update them. The Widows installer will trigger a machine reboot so that the .dlls are unloaded and the upgrade can complete. As when the node upgrade is triggered from the Configuration Manager it is a silent, unattended install. No popups would appear on the node host to prompt users about the reboot. This is normal in silent installations / upgrades.
解决办法
To upgrade Enterprise Reporter, you should:
Disable clusters to stop discoveries from being sent to the nodes. (The associated nodes will also be disabled).
Cancel any jobs running on the nodes to stop data from writing to the Enterprise Reporter database.
Cancel any report jobs running or scheduled to prevent Report Manager from accessing the database.
Create a backup of the database.
Note the port number being used by the Enterprise Reporter server.
Upgrade the Enterprise Reporter components.
Upgrade the nodes.
If there are any manually configured nodes, upgrade them manually.
Enable any disabled clusters to resume discoveries.