지금 지원 담당자와 채팅
지원 담당자와 채팅

DR Series Software 3.2.6 - Release Notes

Supported software and hardware

Supported software and hardware

For a complete list of the supported hardware and software for the DR Series system, see the DR Series System Interoperability Guide. You can download this guide by visiting support.quest.com/DR-Series and selecting your specific DR Series system.

What's new in this release

What’s new in this release

Release 3.2.6.2

The following list describes the features and enhancements that are included in the current 3.2.6.2 release.

Release 3.2.6.1

For your reference, the following list describes the features and enhancements that were included in the previous 3.2.6.1 release.

Support for the hardware versions for the Russia market — This version of the software supports the hardware available for the Russian market.
Support for the DR2000v — The latest version of the DR2000v can be used with/registered on DR Series hardware systems running either release versions 3.2.0.2 or 3.2.6.1.

FIPS 140-2 support has been added.

New cleaner statistic for CLI — When using the stats –cleaner CLI command, the last time the cleaner completed is now displayed.

Release 3.2.6

For your reference, the following list describes the features and enhancements that were included in the 3.2.6 release.

Support for new models of the DR Series system hardware — This release of the DR Series system software supports the following new hardware appliance models: DR4300e, DR4300, and DR6300.

Open Issues

Open Issues

ID

Issue

Description/Workaround

26585

When performing a RM reset on the DR4300e, it may fail during reboot after installing the RM image.

Reset the DR Series system from iDRAC console if RM installation appears to hang. The system will boot from the hard disk and continue with the RM installation.

25832

RDNFS binary upgrade fails in RHEL 7 client.

Uninstall any existing RDNFS package and then install the new one.

25820

During a software upgrade in the GUI, an issue occurs on the Software Upgrade page, displaying the Global View link (which is not accessible) and showing the iDRAC address as N/A.

Clicking global view on the menu should not be supported during an upgrade. This can be ignored in the GUI since it cannot be accessed.

24597

CIFS usage graph shows that there are CIFS writes when running iSCSI I/O only.

The statistics reported on the iSCSI graph are accurate. Due to a bug, false statistics are reported on the CIFS graph, which can be ignored. It will be fixed in a future release.

23709

Changing the machine host name does not get updated properly in all components.

This issue does not cause known failures to the normal operation of the DR Series system and can be ignored. It will be fixed in a future release.

20553

Specific umount options do not work for Rapid NFS.

The -l and -f options are not supported in the rdnfs unmount procedure.

20426

Replication traffic that is configured to go through an assigned bond may still run through the default bond (bond0).

If you want to run replication traffic through another bond interface, contact Technical Support to update the route.

18837

Manual modifications made to the Rapid NFS rdnfs.cfg file are not preserved between plug-in updates.

Manually modify the rdnfs.cfg again after upgrading the plug-in.

17294

A NetVault Backup data copy or duplication will stop if the DR Series system goes into maintenance mode as it moves into a read-only condition when this occurs.

Restart the datacopy operation after the DR Series system enters the operational mode.

17206

Advanced networking allows you to change the IP of an interface that is part of a replication link.

Understand your current configuration before adding new advanced networking configuration so that you do not impact the current system configuration.

16280

When you try to get replication statistics, the system displays the Software error: Use of uninitialized value in division (/) at helper.pl line 3548 error.

This is due to the replication target not being in an operational state. Correct the replication target and refresh or use the CLI. The information is available by using the command line. We will correct this error in a future release.

Known issues and resolutions

Known issues and resolutions

The following table lists known issues and related resolutions addressed in the current DR Series system release.

ID

Issue

Resolution

30465

New Quest DLV license support.

This feature has been added in release 3.2.6.2 to support Quest and Dell license formats.

29733

Incorrect output was displayed when using the command cleaner --show_log_files.

This issue has been addressed in release 3.2.6.2.

29618

Login issue with login groups.

This issue has been addressed in release 3.2.6.2.

29530

Incorrect stats included in daily report for replication target.

This issue has been addressed in release 3.2.6.2.

29421

Need to increase RPC client timeout for node start/stop.

This issue has been addressed in release 3.2.6.2.

29266

Need to add cleaner tunable parameter for laundry size.

This new feature has been added to release 3.2.6.2. Note that this parameter must be tuned by Technical Support.

28499

Add cleaner GUI usage graph for cleaner details.

This new feature has been added to release 3.2.6.2.

관련 문서

The document was helpful.

평가 결과 선택

I easily found the information I needed.

평가 결과 선택