The Scalable Hardware benchmark measures relational database systems. This benchmark is a subset of the AS3AP benchmark and tests the following:
To learn how to create a Scalable Hardware test in Benchmark Factory, see Create Industry Standard Benchmark Test.
The scale factor determines the amount of information initially loaded into the benchmark tables. For the Scalable Hardware benchmark, each scale factor represents one user accessing the system. Two tables are created in the database, and they are loaded with a varying number of rows.
For each virtual user, a separate set of data must be created. Therefore the scale factor used when loading the database should be the size of the maximum user load. For example, with user loads of 1, 5, and 10, a scale factor of 10 should be used.
The Scalable Hardware benchmark has a scaling factor of one.
Do not load-test against a production server if possible. Load-testing and benchmarking on a production server significantly degrades performance. In some cases, load-testing can cause a server to fail. However, if testing against a production server, take the following precautions:
To reinitialize a testing database, run a job containing a Benchmark Object node.
There are two ways to create a Benchmark Object node:
To learn how to create a TPC-B benchmark test in Benchmark Factory, see Create Industry Standard Benchmark Test.
The Transaction Processing Council is an organization that establishes transaction processing and database benchmark standards. Find a complete overview and detailed explanation of the TPC-B Benchmark, at: http://www.tpc.org/tpcb/default.asp
Transaction Processing Council testing results cannot be published as certified unless the testing procedure is audited and approved by the TPC organization. If not certified, the testing results can be published as a "TPC-B like" test.
The following provides best practices for the TPC-B Benchmark.
Do not load-test against a production server if possible. Load-testing and benchmarking on a production server significantly degrades performance. In some cases, load-testing can cause a server to fail. However, if testing against a production server, take the following precautions:
To reinitialize a testing database, run a job containing a Benchmark Object node.
There are two ways to create a Benchmark Object node:
The TPC-B benchmark is made up of only one transaction that updates three tables and inserts a record into a history table. Inserting one record into one history table limits testing performance. The Benchmark Factory properties page allows the user to set the number of history tables to create during a test. The best ratio of history tables to virtual users is based on database configuration and hardware. The number of history tables to use is determined by the tester.
The TPC-B benchmark scales by a factor of one.
To learn how to create a TPC-C benchmark test in Benchmark Factory, see Create Industry Standard Benchmark Test.
Find a detailed overview of the TPC-C Benchmark at: http://www.tpc.org/tpcc/default.asp.
The TPC-C benchmark is an online transaction processing benchmark that simulates environments that have a number of terminal operators that send transactions to a database. This benchmark is focused on the concept of an order-entry type environment with transaction that include orders, payment recording, order status, and stock level monitoring. This benchmark portrays the activities of a wholesale supplier. However, the TPC-C is not limited to one particular business segment. It can represent numerous categories of a business that sell or distribute products and services.
The TPC-C benchmark simulates a wholesale parts dealer operating out of warehouses. This Benchmark scales as a company, in theory, expands their business or number of facilities. As the TPC-C benchmark scales, so do the number components for the benchmark, for example, the sales districts and customers.
The scale factor determines the amount of information initially loaded into the benchmark tables. For the TPC-C benchmark, each scale factor represents one warehouse as per TPC-C specification. The TPC-C benchmark involves a mix of five concurrent transactions of different types and complexity. The database is comprised of nine tables with a wide range of records.
A maximum of 10 users should be run against each warehouse. For example, user loads of 1, 5, and 10, set the scale to 1. If using other user load values, change the scale factor accordingly.
The TPC-C database consists of the following tables:
|
|
Transaction Processing Council testing results cannot be published as certified unless the testing procedure is audited and approved by the TPC organization. If not certified, the testing results can be published as a "TPC-C like" test.
The following provides best practices for the TPC-C Benchmark.
Do not load-test against a production server if possible. Load-testing and benchmarking on a production server significantly degrades performance. In some cases, load-testing can cause a server to fail. However, if testing against a production server, take the following precautions:
To reinitialize a testing database, run a job containing a Benchmark Object node.
There are two ways to create a Benchmark Object node:
To learn how to create a TPC-D benchmark test in Benchmark Factory, see Create Industry Standard Benchmark Test.
The Transaction Processing Council is an organization that establishes transaction processing and database benchmark standards. Find a complete overview and detailed explanation of the TPC-D Benchmark at: http://www.tpc.org/tpcd/default.asp
Transaction Processing Council testing results cannot be published as certified unless the testing procedure is audited and approved by the TPC organization. If not certified, the testing results can be published as a "TPC-D like" test.
The following provides best practices for the TPC-D Benchmark.
Do not load-test against a production server if possible. Load-testing and benchmarking on a production server significantly degrades performance. In some cases, load-testing can cause a server to fail. However, if testing against a production server, take the following precautions:
To reinitialize a testing database, run a job containing a Benchmark Object node.
There are two ways to create a Benchmark Object node:
The TPC-D benchmark scales by the following factors:
© ALL RIGHTS RESERVED. 이용 약관 개인정보 보호정책 Cookie Preference Center