An error similar to the following is logged during Installation of Archive Manager:
Error was: System.ObjectDisposedException: Cannot write to a closed TextWriter.
at System.IO.__Error.WriterClosed()
at System.IO.StreamWriter.Flush(Boolean flushStream, Boolean flushEncoder)
at System.IO.StreamWriter.Flush()
at AfterMail.Installer.RemoteInstallerService.FileLogger.LogMessage(String message, Boolean append)
at AfterMail.Installer.RemoteInstallerService.InstallerRemotingService.DoLogMessage(String logSource, LogType logType, String message)
at AfterMail.Installer.RemoteInstallerService.InstallerRemotingService.BaseUtilityLogHandler(String logSource, LogType logType, String message)
at AfterMail.Installer.RemoteInstallerService.BaseUtility.DoLog(LogType logType, String message, Object[] param)
There are various causes:
RESOLUTION 1:
Cancel the installer, ensure all services are stopped and kill any of the follwowing processes that are still running using Task Manager, then re-run the installer:
RESOLUTION 2:
Disable any Anti-Virus programs running on the servers specified in the Archive Manager installer and re-run the installer.