Chatta subito con l'assistenza
Chat con il supporto

Foglight for VMware 6.1.0 - User Guide (Lite version)

Using Foglight for VMware Reference Appendix: Alarm Messages Appendix: Metrics

VMW Datacenter Disk IO

This rule monitors for spikes and dramatic drops in disk IO for a datacenter.

VMWDatacenter

Table 53. Rule Definition

The disk usage is no more than 2.2 standard deviations (NumSTDevs) from the mean disk usage.

Normal

None

The disk usage is more than 2.2 but no more than 2.8 standard deviations from the mean disk usage.

Warning

None

The disk usage is more than 2.8 standard deviations from the mean disk usage.

Critical

None

Datastore Rules

This section describes datastore rules.

Rules in this section:

VMW Datastore Estimated Fill Time

This rule determines when the datastore is likely to reach its capacity, based on its present growth rate.

VMWDatastore

Table 54. Rule Definition

At the present growth rate, the datastore will not reach its capacity within 90 days.

Normal

None

At the present growth rate, the datastore will reach its capacity in 90 days or less.

Warning

None

At the present growth rate, the datastore will reach its capacity in 30 days or less.

Critical

Send email to VMware administrator

At the present growth rate, the datastore will reach its capacity in 7 days or less.

Fatal

Send email to VMware administrator

VMW Datastore Inactive

This rule detects when a datastore becomes inactive in vSphere.

VMWDatastore

The datastore is currently active.

Normal

None

The datastore is currently inactive.

Warning

None

Related Documents

The document was helpful.

Seleziona valutazione

I easily found the information I needed.

Seleziona valutazione