This command displays Fibre Channel information in the current QoreStor.
fc --show --verbose fc --show --target
For fc --show --verbose:
Target port: Slot 6 Port 0 Port WWN: 50:00:65:b8:36:69:96:00 Node WWN: 50:00:65:b8:36:69:90:00 Symbolic node name: "Dell Inc.: Dell DR4300" Card description: QLogic QLE2662 Dual Port FC16 HBA Firmware version: 8.01.02 Port state: Online Port type: NPort (fabric via point-to-point) Port speed: 16 Gbit Port Enabled: Yes Container: test2 LUN: 1 Type: Media changer (L700) Backing store path: /dev/sg76 LUN: 2 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg36 LUN: 3 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg37 LUN: 4 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg38 LUN: 5 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg39 LUN: 6 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg40 LUN: 7 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg41 LUN: 8 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg42 LUN: 9 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg43 LUN: 10 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg44 LUN: 11 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg45 Initiators: 21:00:00:24:ff:76:58:66 Target port: Slot 6 Port 1 Port WWN: 50:00:65:b8:36:69:96:01 Node WWN: 50:00:65:b8:36:69:90:00 Symbolic node name: "Dell Inc.: Dell DR4300" Card description: QLogic QLE2662 Dual Port FC16 HBA Firmware version: 8.01.02 Port state: Online Port type: NPort (fabric via point-to-point) Port speed: 16 Gbit Port Enabled: Yes Container: test2 LUN: 1 Type: Media changer (L700) Backing store path: /dev/sg76 LUN: 2 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg36 LUN: 3 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg37 LUN: 4 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg38 LUN: 5 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg39 LUN: 6 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg40 LUN: 7 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg41 LUN: 8 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg42 LUN: 9 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg43 LUN: 10 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg44 LUN: 11 Type: Magnetic tape (ULT3580-TD4) Backing store path: /dev/sg45 Initiators: 21:00:00:24:ff:76:58:66
For fc --show --target:
Target port: Slot 6 Port 0 Port WWN: 50:00:65:b6:33:63:14:88 Node WWN: 50:00:65:b6:33:63:14:80 Symbolic node name: "Dell Inc.: Dell DR4300" Card description: QLogic QLE2662 Dual Port FC16 HBA Firmware version: 8.01.02 Port state: Online Port type: NPort (fabric via point-to-point) Port speed: 16 Gbit Port Enabled: Yes Target port: Slot 6 Port 1 Port WWN: 50:00:65:b6:33:63:14:89 Node WWN: 50:00:65:b6:33:63:14:80 Symbolic node name: "Dell Inc.: Dell DR4300" Card description: QLogic QLE2662 Dual Port FC16 HBA Firmware version: 8.01.02 Port state: Online Port type: NPort (fabric via point-to-point) Port speed: 16 Gbit Port Enabled: Yes
This command displays the current Fibre Channel sessions in the current QoreStor system.
fc --sessions --topology
fc --sessions
--condensed
Target port: 50:00:65:b6:33:63:14:88 Initiators connected: 10:00:00:90:fa:a0:ae:0a 50:0a:09:80:00:88:a7:71 50:0a:09:80:06:8d:9a:40 c0:03:ff:bd:1d:69:00:48 Target port: 50:00:65:b6:33:63:14:89 Initiators connected: 10:00:00:90:fa:cf:49:5e c0:03:ff:bd:1d:69:00:54 c0:03:ff:bd:1d:69:00:58 c0:03:ff:bd:1d:69:00:60
For fc --sessions --condensed:
Initiators connected. 10:00:00:90:fa:a0:ae:0a 50:0a:09:80:00:88:a7:71 50:0a:09:80:06:8d:9a:40 c0:03:ff:bd:1d:69:00:48 10:00:00:90:fa:cf:49:5e c0:03:ff:bd:1d:69:00:54 c0:03:ff:bd:1d:69:00:58 c0:03:ff:bd:1d:69:00:60
This command displays the command-specific help for the fc commands.
fc --help
Usage: fc --show [--verbose] [--target] fc --sessions [--topology] [--condensed] fc --help fc <command> <command-arguments> command can be one of: --show Displays command specific information. --sessions Show FC sessions For command-specific help, please type fc --help <command> eg: fc --help show
The iSCSI commands allow you to manage iSCSI connections when you are using virtual tape library (VTL) containers.
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. 使用条款 隐私 Cookie Preference Center