While installing the Performance Analysis (PA) repository the following error occurs:
The repository operation failed.
Connection Details
...
Generated the following error:
ERROR: Scenario initialization fault
Location:
Error Code: -81000
Installation without repository works fine.
CAUSE 1: Invalid Performance Analysis database objects in the monitored instance. To diagnose run the following query as PA user in the monitored database:
Select object_name, object_type, status from user_objects where status = INVALID;
CAUSE 2: Corrupt history collection on the middleware. If you are connecting to the instance with the PA client you will get and error message stating: "History collection is not configured".
CAUSE 3: Not enough space available in the repository. This can be diagnosed by examining the repository log under <install dir>/agents/StealthCollect/7.0/<HOST-INSTANCE>quest_sc_rep/var/stderr.quest_sc_rep
© 2024 Quest Software Inc. ALL RIGHTS RESERVED. 使用条款 隐私 Cookie Preference Center