An ORA-01843 error results followed by unknown exception errors when attempting to view data for a table in the Schema Browser requiring TOAD to be shutdown.
The cause of the problem is an invalid date filter on a non-date field for the table.
For example, the following filter was entered for FIELD1 where FIELD1 is a varchar2 column:
FIELD1 = TO_DATE('12/12/2004','DD/MM/YYYY').
WORKAROUND:
None
STATUS:
This issue is fixed in TOAD 8.6.0.38. This version can be downloaded at http://support.quest.com/prod_upgrade_alert.asp.