Chat now with support
Chat with Support

Foglight for Storage Management Shared 4.9 - User Guide

Getting Started Configuring Agents to Monitor Storage Devices
Brocade SAN Switches Cisco SAN Switches Dell Compellent Arrays Dell EqualLogic PS Series Array Groups EMC CLARiiON CX Series Arrays (CLI) EMC CLARiiON, VNX, or VMAX Storage Arrays (SMI-S) EMC Isilon EMC VPLEX Hitachi Data Systems AMS, USP, and VSP HP EVA Storage Arrays HP 3PAR Arrays NetApp Filers Configuration Procedures
Managing Agents Using Foglight for Storage Management Monitoring Storage Performance Investigating Storage Devices Investigating Storage Components Investigating VPLEX Storage Troubleshooting Storage Performance Managing Data Collection, Rules, and Alarms Understanding Metrics Appendix: Collection Target Support Matrix Online-Only Topics

Requirements for NetApp Filers

Your environment must meet the following requirements:

Table 10. List of calls

aggr-get-iter

lun-get-iter

qtree-list

aggr-list-info

lun-get-occupied-size

quota-report

aggr-space-get-iter

lun-get-serial-number

snapshot-delta-info

aggr-status-get-iter

lun-get-space-reservation-info

snapshot-get-reserve

cifs-share-get-iter

lun-list-info

snapshot-list-info

cifs-share-list-iter-end

lun-map-get-iter

snmp-get

cifs-share-list-iter-next

lun-map-list-info

snmp-get-next

cifs-share-list-iter-start

net-interface-get-iter

storage-disk-get-iter

cluster-identity-get

nfs-exportfs-list-rules

system-api-list

disk-list-info

nfs-exportfs-list-rules-2

system-get-info

fcp-adapter-get-iter

perf-object-counter-list-info

system-get-node-info-iter

fcp-adapter-list-info

perf-object-get-instances

system-get-ontapi-version

fcp-interface-get-iter

perf-object-get-instances-iter-end

system-get-version

fcp-node-get-name

perf-object-get-instances-iter-next

vfiler-list-info

fcp-port-name-get-iter

perf-object-get-instances-iter-start

volume-get-iter

igroup-get-iter

perf-object-instance-list-info

volume-get-root-name

iscsi-interface-get-iter

perf-object-instance-list-info-iter

volume-list-info

iscsi-node-get-name

portset-get-iter

volume-options-list-info

iscsi-service-get-iter

portset-list-info

vserver-get-iter

In 7-Mode, this command line can be used to create a role with only the limited permissions required for monitoring.
In cluster mode, the newer security login commands can be used to create a role with the appropriate permissions.

api-aggr-get-iter,

api-aggr-status-get-iter

storage aggregate show

api-aggr-space-get-iter

storage aggregate show-space

api-cifs-share-get-iter

vserver cifs share show

api-cluster-identity-get

cluster show

api-disk-list-info

storage disk show

api-fcp-adapter-get-iter

network fcp adapter show

api-fcp-interface-get-iter

vserver fcp interface show

api-fcp-port-name-get-iter

vserver fcp wwpn-alias show

api-iscsi-service-get-iter

vserver iscsi show

api-lun-get-iter

lun show

api-lun-map-get-iter

lun mapped show

api-net-interface-get-iter

network interface show

api-nfs-service-get-iter

vserver nfs show,

vserver nfs status

api-perf-object-counter-list-info

statistics catalog counter show

api-perf-object-get*

statistics show

api-perf-object-instance-list-info-iter

statistics catalog instance show

api-portset-get-iter

lun portset show

api-qtree-list-iter

volume qtree show

api-quota-report-iter

volume quota report

api-snapshot-*

volume snapshot show,

volume snapshot policy show

api-storage-disk-get-iter

storage disk show

api-system-get-node-info-iter

system node image show

api-system-get-version

version

api-volume-get-iter

volume show

api-vserver-get-iter

vserver show

igroup-get-iter

lun igroup show

 

NOTE:  

Configuring Agents to Monitor NetApp Filers

Configure an agent for each NetApp filer you want to monitor. For details, see Configuring Agents to Monitor Storage Devices.

Configuration Procedures

The preceding sections link to the folowing configuration procedures:

Configuring Agents to Monitor Storage Devices

1
On the navigation panel, under Homes, click Storage Environment.
2
Click the Administration tab.
3
Click Configure Agent for Storage Device Monitoring.
4
In the Add/Edit Agent section, select an agent manager host from the Agent Manager drop-down list.
5
In the Add/Edit Agent section, configure the agent settings:
a
Select the type of storage device from the Resource Type and Model drop-down lists, as indicated in Table 12.
b
In the IP Address field, type the IP address of the server hosting the agent manager.
c
If the Agent uses a non-default port, type the port number in the Port field. Ensure that this port is open and that traffic is permitted between the device and the Agent Manager host.
d
e
Click Add.
If the agent is incorrectly configured, the Validated column provides details to help you troubleshoot the issue. For additional information, see Resolving Connection Attempt Errors.
9
Click OK to exist the Storage Device Setup dialog.

Brocade SAN Switches

FC Switch

Brocade

Cisco SAN Switches

FC Switch

Cisco

Dell Compellent Arrays

Storage Array

Dell Compellent

Dell EqualLogic PS Series Array Groups

Storage Array

Dell EqualLogic

EMC CLARiiON CX Series Arrays (CLI)

Storage Array

EMC CLARiiON using CLI

EMC CLARiiON, VNX, or VMAX Storage Arrays (SMI-S)

Storage Array

EMC VNX/CLARiiON/VMAX - SMIS

EMC Isilon

Storage Array

EMC Isilon

Hitachi Data Systems AMS, USP, and VSP

Storage Array

HDS AMS/UPS/VSP

HP EVA Storage Arrays

Storage Array

HP EVA

HP 3PAR Arrays

Storage Array

HP 3PAR

NetApp Filers

Filer

NetApp

Related Documents

The document was helpful.

Select Rating

I easily found the information I needed.

Select Rating