Chat now with support
Chat with Support

vRanger 7.7.1 - Integration Guide for EMC Data Domain Boost (DD Boost)

Enabling replication

Previous Next



Enabling replication

When using EMC® Data Domain® Boost (DD Boost™) with vRanger, replication is configured through the vRanger interface. For instructions on enabling replication, see Configuring repository replication.

Enabling low-bandwidth optimization

Previous Next



Enabling low-bandwidth optimization

To enable the low-bandwidth option, enter:

Enabling or disabling the low-bandwidth optimization option does not require a restart of the EMC® Data Domain® file system. After enabling low-bandwidth optimization, however, you need to run a full cleaning cycle on the Data Domain system for it to be effective.

Low-bandwidth optimization can be monitored and managed with the command ddboost file replication or from the Enterprise Manager Data Management > DD Boost view. For more information, see the EMC Data Domain Operating System Administration Guide.

No configuration changes are necessary on the backup server as this feature is transparent to the data protection applications.

Notes:
For more information on this feature, see the EMC Data Domain Operating System Administration Guide.

Enabling encrypted file replication

Previous Next



Enabling encrypted file replication

To enable the encrypted file-replication option, enter:

# ddboost file-replication option set encryption enabled

The output indicates that the encryption you requested was enabled.

For more information, see the command ddboost file-replication.

No configuration changes are necessary on the backup server as this feature is transparent to the data protection application. Turning on this feature takes additional resources — CPU and memory — on an EMC® Data Domain® system.

Notes:
For more information on this feature, see the EMC Data Domain Operating System Administration Guide.

Installing vRanger

Previous Next



vRanger system requirements

Before installing vRanger and EMC® Data Domain® Boost (DD Boost™), ensure that you read and understand the requirements and limitations of both products. The following topics summarize the system requirements for vRanger.

For vRanger and DD Boost to integrate, you must use the following versions:

At least one EMC® Data Domain® device running:
Related Documents

The document was helpful.

Select Rating

I easily found the information I needed.

Select Rating