When connected to Netezza, and trying to drag a Table into the Query Builder, Toad hangs, the table is never shown in the query builder, Toad becomes unusable and one has to kill it from the Task Manager.
Cause
The "Database" in the TDP connection, and, the "Database" in the DSN definition are different.
Resolution
Make sure there isn't a mismatch between TDP's "Database" entry and DSN's "Database" entry.
Also, entering only a value for the database entry, like shown below "System", and leaving the schema blanked, one may use any database in the TDP's "Database" entry.