The tables below provide more detailed information on NetVault Backup and vRanger feature compatibility with QoreStor.
Feature | NVBU 12.0.1 | NVBU 12.1 | NVBU 12.2 | NVBU 12.3 | NVBU 12.4 |
---|---|---|---|---|---|
Integrated RDA plug-in version | 4.1.0.234 | 4.1.0.234 | 4.1.0.237 | 4.1.0.263 | 4.1.0.266 |
Compatible RDA plug-in versions |
4.1
|
4.1 |
4.1 |
4.1 |
4.1 |
Secure Connect WAN restart-abilityTo enable secure WAN reconnection functionality, the Secure Connect client must be version 4.1.0.265 and the QoreStor server version must be 5.1.0.833. 1 |
Yes | Yes | Yes | Yes | Yes |
Create storage groups and containers from DMA | Yes | Yes | Yes | Yes | Yes |
OpDup DR to QoreStorRequires DR OS 4.0 or later.2 | Yes | Yes | Yes | Yes | Yes |
OpDup QoreStor to DR | Yes | Yes | Yes | Yes | Yes |
Feature | vRanger 7.6.5 | vRanger 7.7 | vRanger 7.8 |
Integrated RDA plug-in version | 4.03 | 4.0.3202.1 | 4.1.0.263 |
Secure Connect WAN restart-ability1 |
No | No | No |
Create storage groups and containers from DMA | No | No | No |
OpDup DR to QoreStor2 | Yes | Yes | Yes |
OpDup QoreStor to DR | Yes |
Yes (w/ DRv4.0.3203.1b) |
Yes (w/ DRv4.0.3203.1b) |
This section lists the supported configuration limits for the QoreStor system.
Feature | Cloud-optimized | Standard | Large |
---|---|---|---|
Maximum containers |
16 | 32 | 64 |
Maximum VTL containers | 1 | 2 | 4 |
Maximum storage groups |
5 | 5 | 5 |
Maximum streams | 32 | 64 | 128 |
Maximum connections - CIFS/ Rapid CIFS | 16 | 32 | 64 |
Maximum connections - NFS/ Rapid NFS | 16 | 32 | 64 |
Maximum connections - RDA | 32 | 128 | 256 |
Maximum connections - OST | 32 | 128 | 256 |
Maximum replications | 16 | 32 | 64 |
The information in the sections below is intended to help you properly size your QoreStor server.
The specifications detailed in Hardware references were constructed with the performance guidelines listed below in mind. Please review the performance guidelines below and select an option suitable for your environment. Use that same reference in the Hardware references section to identify the representative reference architecture.
Reference Guidelines | CPU (cores) |
Memory (GB) | NIC Minimum | IO Minimums | Inbound bandwidth | ||
SSD Support |
IOPS BW |
IO spindles |
Ingest Rate Max @ 90% deduplication rate | ||||
Extreme | 32-64 | 128+ | 4 x 10GbE | Required |
IOPs = 100K+ BW = 700MiB/Sec |
RAID6 48+ |
30+ TB/HR |
Enterprise | 32-64 | 64-128 | 2x 10GbE | Optional |
IOPs = 20K+ BW = 300MiB/Sec |
RAID6 24-48 |
20 TB/HR |
Standard | 8-32 | 32-64 | 2x 10GbE | Optional |
IOPs = 10K+ BW = 200MiB/Sec |
RAID6 8-12 |
10 TB/HR |
Starter | 4-8 | 24-32 | 4+ x 1GbE | NA |
IOPs = 5K+ BW = 100MiB/Sec |
RAID5-6 4-8 |
5 TB/HR |