Unable to connect to the "<database>" (4324888)

When trying to setup the connection and try to connect, Unable to connect to the "" error shows. ... There is no problem with the connection since user can successfully connect via command line. ... Ensure that IBM 9.7 FP5 or above version client is installed.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 329 vues
Knowledge Article
Database alias shows up blank in spotlight connection window (4234151)

When trying to make a new connection, the database alias drop-down is blank and will not populate. ... Opening the DB2 client, the directory show there are alias names showing. ... Without the database alias, the Spotlight connection window will gray out the OK button.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 773 vues
Knowledge Article
Which software do I select for Spotlight on DB2 for LUW? (4274234)

From www.quest.com Which software do I select for Spotlight on DB2 for LUW? ... The Client software is the GUI module that must be installed before connecting to the agents. ... The Agent software depends on which database server is in your environment.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 464 vues
Knowledge Article
Unable to monitor DB2 8.2 with Spotlight on DB2 (4325799)

DB2 8.2 is unsupported both by Spotlight 6.7 and 6.8. ... For the complete system requirements, check the release notes from Quest Support Portal.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 198 vues
Knowledge Article
Spotlight alerts red alarm on DB2 automatic storage (4283333)

When using the feature 'Automatic' storage, Spotlight on DB2 for LUW does not recognize this and always reports that the DMS utilization is very high in some DB2 instances. ... Is there a way to eliminate this?

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 244 vues
Knowledge Article
Tablespace Analysis gives the error: The database alias name or database name 0 could not be found (4278993)

Drilling down into "Tablespace Analysis | Tablespaces" tab, double-clicking on a tablespace name and selecting the Tables tab results in the error: ... SQL1013N The database alias name or database name "0" could not be found.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 1174 vues
Knowledge Article
How to setup an action rule; when the time of the last backup has surpassed a week? (4278589)

Spotlight on DB2 can show "the last backup" information. ... User wants to setup an action rule to do something when "the last backup" time is over 7 days (eg. send a mail, or backup again). ... How to setup this action rule?

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 263 vues
Knowledge Article
Are there performance tuning and session browser features in Toad for DB2? How to monitor applications? (4316390)

Are there performance tuning and session browser features in Toad for DB2? ... How to monitor applications? ... Toad for DB2 is more of an administration tool and does not provide features for performance testing and tuning.

Produit(s): Toad for DB2, Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 972 vues
Knowledge Article
"An error occurred while refreshing the table "Stmt" in connection" (4273773)

Error when launching classic Spotlight on DB2 6.2 from QCDB2 v 4.9.4, connecting to DB2 v 9.1: ... Spotlight on DB2 for LUW 6.2.0.22 ... An error occurred while refreshing the table "Stmt" in connection "DB_name ( test )".

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 261 vues
Knowledge Article
An error occurred while refreshing the table "DBaseAll" in connection "\PRD1" (4280565)

Now Spotlight on DB2 for LUW Version: 6.7.2.105 does not work correctly, and here is the error... ... Spotlight on DB2 for LUW 6.7.2.105 - An error occurred while refreshing the table "DBaseAll" in connection "\PROD".

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 248 vues
Knowledge Article
Error during connection: "QCC10000E - Unable to allocate environment handle for DBConnect" (4274660)

User installed both versions of the DB2 client v8.2 and v9.1 onto his client machine. ... When he launched Spotlight on DB2 and tried to create a new connection he received the following error: ... "QCC10000E - Unable to allocate environment handle for DBConnect."

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 707 vues
Knowledge Article
The Spotlight DB2 Home Page shows no connections, no activity, no backup (4274817)

The Spotlight main Home Page shows no connections or activity and indicates no last backup. ... Make sure you are on 6.9.3 before you apply the patch.</p><div></div><div> Spotlight.exe</div><div> ConnDB2.dll</div><div></div><div>With Spolight DB2 closed, Go to &quot;C:\Program Files (x86)\Quest Software\Spotlight on IBM DB2 LUW\Console\&quot; or where ever the install path is for your Spotlight.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 739 vues
Knowledge Article
Does Spotlight on DB2 have a database up time report? (4270422)

Can Spotlight on DB2 report on database up time?

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 892 vues
Knowledge Article
Error during connection: "SQL1476N The current transaction was rolled back because of error -973. SQLSTATE=40506" (4269404)

User upgraded DB2 v8 to V9.1 and used Spotlight for DB2 version 6.2 to connect to the database. ... User receives below error either on the SQL tab or on the History browser: ... Message: ... An error occurred while refreshing the table "DBaseHistory" in connection "EDT1D ( DB2EDT1D )".

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 2892 vues
Knowledge Article
Error: "Exception: Assertion failure" on Spotlight on DB2 (4269126)

SOLUTION: Rename configUDB.ini to the different one. ... 1) Make sure that Spotlight is not running ... 2) Go to your Spotlight on DB2 install directory on your Windows machine and see if you have a file named configUDB.ini.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 375 vues
Knowledge Article
What is new in Spotlight on IBM DB2 6.9.3? (4224646)

Additional information can be located in 6.9.3 Release Notes Technical Documentation. ... Spotlight 6.9.3 version can be downloaded from here.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 711 vues
Knowledge Article
Getting "Invalid plug-in id in spotlight console." when opening application. (4273952)

I just installed Spotlight on DB2 and launched it right away and got error: "Invalid plug-in id in spotlight console."

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 317 vues
Knowledge Article
Spotlight does not show activity (4339544)

Spotlight on DB2 shows data but not activity, but Spotlight on UNIX shows both data and activity. ... All graphs seems to be frozen and don&#39;t show any movements. ... <p><br>Please set these 2 switches and wait for 15~30 seconds for Spotlight to refresh:</p> <p>db2 update monitor switches using BUFFERPOOL on global<br>db2 update dbm cfg using DFT_MON_BUFPOOL on</p> <p>Then...</p> <p>1)

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 114 vues
Knowledge Article
What permissions are needed (4335271)

1. Does Spotlight require a local system-admin level ID to run successfully? ... 1.Spotlight need local administrator or belong to "DB2ADMIN" or "DB2USER" user group. ... This privilege is for run DB2 client DLLs.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 826 vues
Knowledge Article
WLM startup task ran out of storage due to error message ICH70001I (4278994)

From Quest Central for DB2, a DBA tried to reorg a table, but the job never completed. ... The WLM startup job runs out of storage space due to many warning messages stating ICH70001I that were issued every 30 seconds.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 288 vues
Knowledge Article
Error signature on AppName: Monitor.exe and ModName: kernel32.dll in Spotlight (4282933)

User tried to launch Classic Spotlight on DB2 from Quest Central for DB2 v 5.0.1 and received the following error message: ... Please install the standalone Spotlight on DB2 v 6.2.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 354 vues
Knowledge Article
Error: "Invalid key on Spotlight on DB2." (4283279)

Error received when manually typing licensing key and message id: ... Copy and paste key and message id without any extra spaces or returns.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 298 vues
Knowledge Article
DB2 FP16 Installation "Connect failure SQL30082N reason code 15" (4283495)

We have fixed DAS server, Control Center and QCDB2 are working fine. ... Spotlight connection also works fine. ... On database drilldown, we got error SQL30082N reason code 15 when we clicked on OK button and got same sql code but reason code 3.

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 661 vues
Knowledge Article
'Cannot refresh a table without a live connection' (4255001)

As soon as user starts Spotlight he gets the following error message. ... Spotlight on DB2 for LUW 6.5.1.9 ... 7E418734 (user32.00007734) 7E418816 (user32.00007816) 7E4189CD (user32.000079CD) 7E4196C7 (user32.000086C7) 00490F58 (Spotlight.0008FF58) 0078333D (Spotlight.0038233D) 7C816FE7 (kernel32.00015FE7)

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 172 vues
Knowledge Article
'The following internal error occurred: Interface not supported' (4260237)

On Spotlight on DB2 v 6.7.0.14, user connected to a Database with 64 partitions, Shown client applications, drilldowned to detail, Clicked on Unit of Work-SQL and got internal error: The following internal error occurred: Interface not supported

Produit(s): Spotlight on DB2
Dernière mise à jour le: 07/05/2023
NA rating | 403 vues
Knowledge Article
Rechercher tous les produits
Contenu recommandé
Chargement des résultats
Outils libre-service
Base de connaissances
Notifications et alertes
Support produits
Téléchargements de logiciels
Documentation technique
Forums utilisateurs
Didacticiels vidéo
Flux RSS
Nous contacter
Support Technique
Afficher tout