An error is logged when the SYNCHRONIZE USER SID HISTORY option is enable in the profile settings and SIDHistory is not set in the target object. The error indicates the reason for failure is "inappropriate authentication" and may be similar to the below message:
The Source Credentials in the Settings>Connections>Source section of the profile has been set using the UPN of the source service account and the UPN suffix of this account does not match the domain.
Example: The service account is BTAdmin@altdomain.local and the domain name is domain.local